beautypg.com

Power specifications, Quickspecs – HP ProLiant G6 Server DL320 User Manual

Page 38

background image

HP 500W Power Supply
Part Number - AC 500W PSU

537150-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)
(Hz)

47/63

Nominal Input Voltage (Vrms)

100

120

200

220

230

240

Maximum Rated Output
Wattage

500

500

500

500

500

500

Nominal Input Current (A rms)

5.74

4.99

2.86

2.58

2.46

2.36

Max Rated Input Wattage Rating
(Watts)

568

568

562

556

556

556

Max. Rated VA (Volt-Amp)

574

574

573

567

567

567

Efficiency (%) at Max. Rated
Output Wattage

88

88

89

90

90

90

Power Factor

0.99

0.99

0.98

0.98

0.98

0.98

Leakage Current (mA)

0.42

0.50

0.81

0.91

0.95

1.00

Max. Inrush Current (A peak)

30

30

30

30

30

30

Max. Inrush Current duration
(mS)

20

20

20

20

20

20

Maximum British Thermal Unit
Rating (BTU-Hr)

HP 460W Power Supply
Part Number - AC 460W PSU

515740-B21

Input Voltage Range (Vrms)

100 to 240

Frequency Range (Nominal)
(Hz)

50/60

Nominal Input Voltage (Vrms)

100

120

200

208

220

230

240

Maximum Rated Output
Wattage

460

460

460

460

460

460

460

Nominal Input Current (A rms)

5.5

4.5

2.6

2.5

2.4

2.3

2.2

Max Rated Input Wattage Rating
(Watts)

526

520

505

505

503

503

503

Max. Rated VA (Volt-Amp)

548

542

527

527

524

524

524

Efficiency (%) at Max. Rated
Output Wattage

87.5

88.5

91

91

91.5

91.5

91.5

Power Factor

0.97

0.97

0.97

0.97

0.97

0.97

0.97

Leakage Current (mA)

0.42

0.50

0.83

0.87

0.92

0.96

1.00

Max. Inrush Current (A peak)

30

30

30

30

30

30

30

Max. Inrush Current duration
(mS)

20

20

20

20

20

20

20

Maximum British Thermal Unit
Rating (BTU-Hr)

1794

1773

1725

1725

1715

1715

1715

QuickSpecs

HP ProLiant DL320 Generation 6

Power Specifications

DA - 13344 Worldwide QuickSpecs — Version 19 — 4.22.2010