Troubleshooting

26

311772G

Speed of application slow or slower

Material too thick

Thin material.

Nozzle too small

Change nozzles to a larger size. See
Operation manual 311768.

Too much air being used.

Partially close gun air valve to reduce
air flow.

Pump hose worn

Replace hose.

Plugged or dirty gun

Relieve Pressure, page 6. Clean
gun.

Kinked hose

Unkink hose.

Gun adjustment set too low

Increase flow adjustment with flow
adjustment nut.

Too many items on same circuit

Unplug other items from circuit.

Extension cord too long or wrong
gauge

Use a different extension cord. Refer
to Grounding and Electric Require-
ments, page 6.

Intermittent flow/sputtering

Hopper connection not tight

Check gasket. TIghten connection.

Debris in system

Clean system.

Quick disconnect does not stay con-
nected.

Dirty or corroded fitting

Clean thoroughly. Soak in oil. Apply a
few drops of light oil.

Gun will not shut off

Worn nozzle or needle.

Relieve Pressure, page 6. Replace
worn parts.

Debris in needle passage

Relieve Pressure, page 6. Clean.

Fluid leaking at Flow Adjustment Nut Damaged seal.

Relieve Pressure, page 6. Replace
seal.

Fluid leaking out of either plug

Missing or damaged o-rings

Relieve Pressure, page 6. Replace
o-rings.

Gun damaged

Replace gun.

Needle adjustment won’t adjust

Dirty threads

Clean threads.

Nozzle not on gun

Put nozzle on gun.

Problem

Cause

Solution