Warning, Helpful tip – haier DWL3025 User Manual
Page 22
21
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in terminal
box. Do not use an extension cord. Failure to do so can result
in death, fire, or electrical shock.
1. Direct wire method:
Install strain relief and route direct wire so that it does
not touch dishwasher motor or lower part of dishwasher
tub. Pull direct wire “A” through hole in terminal box.
2. Connect the wire “B” as follows using twist-on
connectors “C” sized to connect direct wire to 16-
gauge dishwasher wire:
From bare ground wire “D” into a U-shaped hook.
Wrap ground wire hook clockwise around ground
connector “E” and under the washer “F”. Securely
tighten ground connector “E” and under the washer
“F”.
Securely tighten ground connector “E”. Do not untie
knot in the wires.
HELPFUL TIP:
• Select the proper size twist-on connectors to connect
your household wiring to 16-gauge dishwasher wiring.
• Insert wire ends into twist-n connector. Do not pretwist
bare wire.
• Twist connector.
• Gently tug on wires to be sure both are secured.
Power Supply Wire:
Terminal Box Wire:
White
White
Black
Black
Ground Wire
Ground Wire