Hearth and Home Technologies Heat & Glo SL-550TR-D User Manual
Page 19
![background image](/manuals/92080/19/background.png)
19
Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06
Figure 5.10
H
2
V
2
H
1
V
1
Top Vent - Vertical Termination
Venting with 3 elbows (NG)
V MIN.
SL-550TR-D
SL-750TR-D
SL-950TR-D
H MAX.
H MAX.
H MAX.
V
2
V
1
+ V
2
MIN.
90 Elbow
0.5 ft. 152 mm
0.5 ft.
152 mm
0 ft.
0 mm
*
*
0.5 ft. 152 mm
1 ft.
305 mm
1 ft.
305 mm
2 ft.
610 mm
*
*
1.5 ft. 457 mm
2 ft.
610 mm
2 ft.
610 mm
3 ft.
914 mm
*
*
2.5 ft. 762 mm
4 ft.
1.2 m
4 ft.
1.2 m
5 ft.
1.5 m
*
*
3.5 ft.
1.1 m
6 ft.
1.8 m
6 ft.
1.8 m
7 ft.
2.1 m
*
*
4.5 ft.
1.4 m
14 ft.
4.3 m
14 ft.
4.3 m
15 ft.
4.6 m
*
*
H MAX. =14 FT (4.6 m)
V
1
+ V
2
+ H + H
2
MAX. = 40 FT (12.2 m)
* No specifi c restrictions on this value EXCEPT V
1
+ V
2
+ H + H
2
cannot exceed 40 FT (12.2 m)
NOTE: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 5.3).
Note: Use SL D- Series
components only.
Top Vent - Vertical Termination
Venting with 3 elbows (Propane)
V MIN.
SL-550TR-D
SL-750TR-D
SL-950TR-D
H MAX.
H MAX.
H MAX.
V
2
V
1
+ V
2
MIN.
90 Elbow
1.5 ft. 457 mm
Not allowed
Not allowed
*
*
0.5 ft. 152 mm 1.5 ft. 457 mm
1 ft.
305 mm
1 ft.
305 mm
*
*
1.5 ft. 457 mm
3 ft.
914 mm
3 ft.
914 mm
3 ft.
914 mm
*
*
2.5 ft. 762 mm
5 ft.
1.5 m
5 ft.
1.5 m
5 ft.
1.5 m
*
*
3.5 ft.
1.1 m
7 ft.
2.1 m
7 ft.
2.1 m
7 ft.
2.1 m
*
*
4.5 ft.
1.4 m
15 ft.
4.6 m
15 ft.
4.6 m
15 ft.
4.6 m
*
*
H MAX. =15 FT (4.6 m)
V
1
+ V
2
+ H MAX. = 40 FT (12.2 m)
* No specifi c restrictions on this value EXCEPT V
1
+ V
2
+ H cannot exceed 40 FT (12.2 m)