beautypg.com

Hearth and Home Technologies Heat & Glo SL-550TR-D User Manual

Page 19

background image

19

Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

Figure 5.10

H

2

V

2

H

1

V

1

Top Vent - Vertical Termination

Venting with 3 elbows (NG)

V MIN.

SL-550TR-D

SL-750TR-D

SL-950TR-D

H MAX.

H MAX.

H MAX.

V

2

V

1

+ V

2

MIN.

90 Elbow

0.5 ft. 152 mm

0.5 ft.

152 mm

0 ft.

0 mm

*

*

0.5 ft. 152 mm

1 ft.

305 mm

1 ft.

305 mm

2 ft.

610 mm

*

*

1.5 ft. 457 mm

2 ft.

610 mm

2 ft.

610 mm

3 ft.

914 mm

*

*

2.5 ft. 762 mm

4 ft.

1.2 m

4 ft.

1.2 m

5 ft.

1.5 m

*

*

3.5 ft.

1.1 m

6 ft.

1.8 m

6 ft.

1.8 m

7 ft.

2.1 m

*

*

4.5 ft.

1.4 m

14 ft.

4.3 m

14 ft.

4.3 m

15 ft.

4.6 m

*

*

H MAX. =14 FT (4.6 m)

V

1

+ V

2

+ H + H

2

MAX. = 40 FT (12.2 m)

* No specifi c restrictions on this value EXCEPT V

1

+ V

2

+ H + H

2

cannot exceed 40 FT (12.2 m)

NOTE: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 5.3).

Note: Use SL D- Series
components only.

Top Vent - Vertical Termination

Venting with 3 elbows (Propane)

V MIN.

SL-550TR-D

SL-750TR-D

SL-950TR-D

H MAX.

H MAX.

H MAX.

V

2

V

1

+ V

2

MIN.

90 Elbow

1.5 ft. 457 mm

Not allowed

Not allowed

*

*

0.5 ft. 152 mm 1.5 ft. 457 mm

1 ft.

305 mm

1 ft.

305 mm

*

*

1.5 ft. 457 mm

3 ft.

914 mm

3 ft.

914 mm

3 ft.

914 mm

*

*

2.5 ft. 762 mm

5 ft.

1.5 m

5 ft.

1.5 m

5 ft.

1.5 m

*

*

3.5 ft.

1.1 m

7 ft.

2.1 m

7 ft.

2.1 m

7 ft.

2.1 m

*

*

4.5 ft.

1.4 m

15 ft.

4.6 m

15 ft.

4.6 m

15 ft.

4.6 m

*

*

H MAX. =15 FT (4.6 m)

V

1

+ V

2

+ H MAX. = 40 FT (12.2 m)

* No specifi c restrictions on this value EXCEPT V

1

+ V

2

+ H cannot exceed 40 FT (12.2 m)