Warning, B. constructing the appliance chase, C. clearances – Hearth and Home Technologies Heat & Glo SL-550TR-D User Manual

Page 8

background image

Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

8

Figure 3.2 Clearances to Combustibles

C

B

D

A

E

H

I

F

FROM TOP

OF HOOD

TO CEILING

G

J

B. Constructing the Appliance Chase

A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that run
on the outside of a building may be, but are not required
to be, installed inside a chase.

Construction of the chase may vary with the type of building.
These instructions are not substitutes for the requirements
of local building codes. Local building codes MUST be
checked.

Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems.
The chase should not break the outside building envelope
in any manner.

Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infi ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling fi restops
should be caulked with high temperature caulk to seal gaps.

C. Clearances

Fire Risk.
• Construct chase to all clearance specifi cations

in manual.

• Locate and install appliance to all clearance

specifi cations in manual

Fire Risk.
Odor Risk.
• Install appliance on hard metal or wood surfaces

extending full width and depth of appliance.

• Do NOT install appliance directly on carpeting,

vinyl, tile or any combustible material other than
wood.

Gas line holes and other openings should be caulked with
high temp caulk or stuffed with unfaced insulation. If the
appliance is being installed on a cement slab, a layer of
plywood may be placed underneath to prevent conducting
cold up into the room.

WARNING

WARNING

Models

A

B

C

D

E

F

G

H

I

J

DVP Pipe SL Pipe

Rough

Opening

(Height)

DVP Pipe SL Pipe

Rough

Opening

(Width)

Clearance

to Ceiling

Non-

Combustible

Floor

Combustible

Flooring

Behind

Appliance

Sides of

Appliance

Front of

Appliance

Rough

Opening

(Width)

Rough

Opening

(Width)

Rough

Opening

(Depth)

Rough

Opening

(Depth)

SL-550TR-D

in.

10

8-5/8

33

27-1/2

16-1/4

37

31

0

0

1/2

1/2

36

mm

254

219

838

699

413

940

787

0

0

13

13

915

SL-750TR-D

in.

10

8-5/8

38-1/4

27-1/2

16-1/4

42

31

0

0

1/2

1/2

36

mm

254

219

971

699

413

1067

787

0

0

13

13

915

SL-950TR-D

in.

10

8-5/8

42 1/4

27-1/2

16-1/4

49

31

0

0

1/2

1/2

36

mm

254

219

1073

699

413

1245

787

0

0

13

13

914