beautypg.com

Hearth and Home Technologies Heat & Glo SL-550TR-D User Manual

Page 13

background image

13

Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

3 in. CLEARANCE

TERMINATION

CAP

FLEX-VENT

1 in.

CLEARANCE

D. Use of Flex Vent

The fl ex vent must be supported with
the spacing between support intervals
not exceeding 4 feet, with no more than
½ inch sag between supports.
A support is required at each change
in venting direction, and in any location
where it is necessary to maintain the
necessary clearance to combustibles.
A simple “up and out” installation
(Figure 5.3) requires only enough
support to maintain the necessary
clearance to combustibles. However,
the vent attachment point and the
fi restop location are considered to be
supports.

Figure 5.3