Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

14

Figure 5.4

E. Vent Diagrams

Top Vent - Horizontal Termination

Venting with 1 elbow (NG)

H

1

V

1

V Minimum

H

1

Maximum

SL-550TR-D

SL-750TR-D

SL-950TR-D

90 Elbow

2 ft.

610 mm

2 ft.

610 mm

1 ft.

305 mm

0.5 ft. 152 mm

2 ft.

610 mm

2 ft.

610 mm

2 ft.

610 mm

1.5 ft. 457 mm

3 ft.

914 mm

3 ft.

914 mm

3 ft.

914 mm

2.5 ft. 762 mm

5 ft.

1.5 m

5 ft.

1.5 m

5 ft.

1.5 m

3.5 ft.

1.1 m

7 ft.

2.1 m

7 ft.

2.1 m

7 ft.

2.1 m

4.5 ft.

1.4 m

15 ft.

4.6 m

15 ft.

4.6 m

15 ft.

4.6 m

H MAX. =15 FT (4.6 m)

V + H MAX. = 40 FT (12.2 m)

Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.

WARNING

NOTE: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 5.3).

Note: Use SL D- Series
components only.

V Minimum

H

1

Maximum

SL-550TR-D

SL-750TR-D

SL-950TR-D

90 Elbow

1.5 ft. 457 mm

Not allowed

Not allowed

0.5 ft. 152 mm 1.5 ft. 457 mm

1 ft.

305 mm

1 ft.

305 mm

1.5 ft. 457 mm

3 ft.

914 mm

3 ft.

914 mm

3 ft.

914 mm

2.5 ft. 762 mm

5 ft.

1.5 m

5 ft.

1.5 m

5 ft.

1.5 m

3.5 ft.

1.1 m

7 ft.

2.1 m

7 ft.

2.1 m

7 ft.

2.1 m

4.5 ft.

1.4 m

15 ft.

4.6 m

15 ft.

4.6 m

15 ft.

4.6 m

H MAX. =15 FT (4.6 m)

V + H MAX. = 40 FT (12.2 m)

Top Vent - Horizontal Termination

Venting with 1 elbow (Propane)

This manual is related to the following products: