Figure 5.5
Top Vent - Horizontal Termination
Venting with 2 elbows (NG)
V Minimum
H
1
+ H
2
Maximum
SL-550TR-D
SL-750TR-D
SL-950TR-D
90 Elbow
0.5 ft. 152 mm 0.5 ft. 152 mm
0 ft.
0 mm
0.5 ft. 152 mm
1 ft.
305 mm
1 ft.
305 mm
1 ft.
305 mm
1.5 ft. 457 mm
2 ft.
610 mm
2 ft.
610 mm
2 ft.
610 mm
2.5 ft. 762 mm
4 ft.
1.2 m
4 ft.
1.2 m
4 ft.
1.2 m
3.5 ft.
1.1 m
6 ft.
1.8 m
6 ft.
1.8 m
6 ft.
1.8 m
4.5 ft.
1.4 m
14 ft.
4.3 m
14 ft.
4.3 m
14 ft.
4.3 m
H + H
1
MAX. =14 FT (4.3 m)
V + H + H
1
MAX. = 40 FT (12.2 m)
V Minimum
H
1
+ H
2
Maximum
SL-550TR-D
SL-750TR-D
SL-950TR-D
90 Elbow
0.5 ft. 152 mm
Not allowed
Not allowed
0.5 ft. 152 mm 0.5 ft. 152 mm
0 ft.
0 mm
0 ft.
0 mm
1.5 ft. 457 mm
2 ft.
610 mm
2 ft.
610 mm
2 ft.
610 mm
2.5 ft. 762 mm
4 ft.
1.2 m
4 ft.
1.2 m
4 ft.
1.2 m
3.5 ft.
1.1 m
6 ft.
1.8 m
6 ft.
1.8 m
6 ft.
1.8 m
4.5 ft.
1.4 m
14 ft.
4.3 m
14 ft.
4.3 m
14 ft.
4.3 m
H + H
1
MAX. =14 FT (4.3 m)
V + H + H
1
MAX. = 40 FT (12.2 m)
Top Vent - Horizontal Termination
Venting with 2 elbows (Propane)
NOTE: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 5.3).