Table 1-2 – Hitachi Universal Storage Platform VM User Manual

Page 20

background image

1-6 Product

Overview

Hitachi Universal Storage Platform V/VM User and Reference Guide

Specifications for the Universal Storage Platform VM

Table 1-2

provides a brief overview of the USP VM specifications.

Table 1-2

Specifications – Universal Storage Platform VM

Controller

Single-rack configuration: controller and up to two drive chassis.
Optional second rack: up to two drive chassis.
Rack: HDS-supplied rack or customer-supplied rack.

Universal Star Network Crossbar Switch

Number of switches

2

Aggregate bandwidth

13.3 GB/sec

Aggregate IOPS

1.2 million

Cache Memory

Boards 8

Board capacity

4 GB, 8 GB, or 16 GB

Maximum 128

GB

Shared Memory

Boards 4

Board capacity

4 GB

Maximum 16

GB

Front-End Directors (Connectivity)

Boards 3

Fibre-channel host ports per feature

8 or 16

Fibre-channel port performance 4

Gb/sec

Maximum number of fibre-channel host ports

48

Virtual host ports

1,024 per physical port

Maximum FICON host ports

24

Maximum ESCON host ports

24

Logical Devices (LDEVs)—Maximum Supported

Open systems

65,536

Mainframe 65,536

Disk Drives and Flash Drives

Capacity (fibre channel)

73 GB, 146 GB, 300 GB, 400 GB, 450 GB

Capacity (SATA)

750 GB, 1 TB

Capacity (flash drive)

73 GB, 146 GB, 200 GB

Number (minimum–maximum)

0–240

Spare drives per system (minimum–maximum) 1–16