beautypg.com

Dehumidification - residential, See “dehumidification - residential, Dehumidification using the cooling system – Honeywell PRESTIGE THX9321 User Manual

Page 105: Set up dehumidification with cooling system

background image

THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

105

68-0311—02

Dehumidification - Residential

The thermostat reads the indoor humidity level and allows the

user to set a dehumidification setting. The thermostat controls

the humidity level using the cooling system or a whole house

dehumidifier.

If humidification and dehumidification are setup to operate in

the same system mode (Heat, Cool, Off) and you are sensing

humidity from one location, the thermostat will automatically

enforce a 15% deadband between the humidification and

dehumidification settings. The thermostat will automatically

switch between humidification and dehumidification to maintain

the desired humidity level.

If humidification and dehumidification are setup to operate in

the same system mode (Heat, Cool, Off) and you are sensing

humidity from two different locations using a remote wireless

indoor sensor (for example, main level and crawl space), the

thermostat will allow humidification and dehumidification to

operate at the same time, and there is no deadband between

humidification and dehumidification settings.

Dehumidification using the Cooling System

When set for A/C with Low Speed Fan or A/C with High Speed

Fan, an overcooling limit can be set from 0 °F to 3 °F (ISU

9070). The thermostat uses the cooling system to reduce

humidity by lowering the temperature up to 3° F below the

current cool setpoint until the desired humidity level is reached.

If set for A/C with Low Speed Fan, configure U1, U2, or U3 as

normally open or normally closed (ISU 9050) and wire to the

Low Speed Fan terminal on the equipment. For example, if the

U1, U2, or U3 terminal is normally closed, it will open when the

thermostat calls for dehumidification.See “Wiring IAQ

Equipment or a Heat/Cool Stage to the Universal Terminals”

beginning on page 149.

NOTE: The thermostat will not lower the fan speed when

the second stage of cooling is on.

Set up Dehumidification With Cooling

System

Some screens shown in this section may not appear on the

thermostat, depending on how you set up dehumidification.

1. Select the Dehumidification Equipment in ISU 9000. See

Fig. 216.

Fig. 216.

2. If optional remote wireless indoor sensors are installed,

you can choose which sensor you want to use for dehu-

midification control. For example, you can use one sen-

sor for humidification control, and another for

dehumidification. See “Wireless Indoor Sensor” begin-

ning on page 130 for more information.

Fig. 217.

3. If you are sensing humidity from two separate locations

(one for humidification and another for dehumidification),

you can select which humidity reading to display on the

home screen. See “Wireless Indoor Sensor” beginning

on page 130 for more information.

Fig. 218.

4. Select the terminals wired to the A/C with Low Speed

Fan. See Fig. 219.

Fig. 219.