CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105
O
C
rated wire.
• Wire must have high temperature insulation.
WARNING
IGNITION
MODULE
(3V)
VALVE
LOW VOLTAGE
PLUG-IN
3V TRANSFORMER
NEUTRAL
HOT
GROUND
FLAME SPARKER/
SENSOR
REMOTE
CONTROL
SEE NOTE 1
VALVE
TRANSFORMER
3 VAC
ORG
WHT
ORG
GRN
ON/OFF
WALL SWITCH
BRN
BRN
BLK
RED
THERMOSTAT
WIRE ASSEMBLY
2045-045
REMOTE JUMPER
WIRE
PLUG IN
IGNITION MODULE 3 VAC
INTERMITTENT PILOT IGNITOR
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
WHITE WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
GROUND TO
FIREPLACE
CHASSIS
LOW VOLTAGE
SEE NOTE 1.
NOTE 1: IGNITION MODULE, VALVE, PILOT AND WALL SWITCH OPERATE ON 3 VOLTS.
120 VAC IS REQUIRED AT JUNCTION BOX UNLESS EQUIPPED WITH BATTERY BACK-UP.
Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram