7.0 TROUBLESHOOTING

PROBLEM OR CONCERN POSSIBLE CAUSE

SOLUTION

Detergent Leak

Disconnected or Kinked Detergent

Pick up Tube

Remove the front cover of the unit and check if the

clear tube is still properly attached or kinked. If it is

not attached then reconnect it or unkink it.

Reservoir Tank won’t hold

Detergent

Chemical Tank Nipple broken

The Chemical Tank Nipple is attached to the inside

wall of the Reservoir Tank. If it is broken you can

order a replacement by emailing us at:

[email protected].

Detergent is not dispensing Incorrect wand is attached to the

Gun

Make sure that the Click-N-Clean

TM

wand is

attached to the Gun and set in the “Detergent

Spray” position Detergent will not dispense with

the Turbo Wand

The Click-N-Clean

TM

wand is not set

in the “Detergent Spray” position.

Turn the shaft of the wand until clicked into the

“Detergent Spray” position (see fig. pag. 1).

Nozzle is clogged with debris

Straighten out a paper clip and insert it into the tip

of the Nozzle. back flush the Nozzle with water.

(see section .)

Detergent to Water ratio

Adjust the Dial-N-Wash

®

dial to increase/decrease

detergent flow. Most power washer chemicals are

generally concentrated within that range so minimal

adjustment is required. If you feel like you are using

more detergent than is required for the application you

can dilute it with regular tap water. (see section .)

Detergent - What to use

We recommend that you use a cleaner which is

specifically designed for power washers. There

are different kinds available depending on the

application. Check with your local Home Depot

store for the product which is best suited for your

needs. Never use Bleach, Ammonia or

Hot water in the unit.

Detergent Tank fills up with

water

Detergent Suction Assembly (the

part which the High Pressure hose

connects to) is defective

The part will have to be replaced, Please email

us directly at:

[email protected].

You can also order the part directly at:

www.huskypowerwasher.com.

Circuit breaker trips or Fuse

blown in Fuse box

Circuit overload

Check that the circuit is rated at 1 amps or

greater. Make sure the unit is plugged into a

dedicated circuit.

Extension cord too long or wire

size too small

Use proper extension cord as recommended in

Owner’s Manual.

Nozzle partially blocked

Clean Nozzle as instructed in section ..

Excessive pressure

Clean Nozzle as instructed in section .

GFCI Plug installation

GFCI Plug malfunction

For GFCI reset procedures see owner’s manual section

.. For instructions regarding the GFCI Plug installa-

tion or malfunction please email us directly at:

[email protected].