beautypg.com

Techspecs, Quickspecs, Hp integrity superdome servers: 16-way, 32-way – HP Integrity Superdome Server User Manual

Page 32: And 64-way, And 64-way techspecs

background image

Superdome Specifications

Superdome Specifications

Superdome Specifications

Superdome Specifications SPU Model Number

SPU Model Number

SPU Model Number

SPU Model Number

Superdome 16-way

Superdome 16-way

Superdome 16-way

Superdome 16-way

Superdome 32-way

Superdome 32-way

Superdome 32-way

Superdome 32-way

Superdome 64-way

Superdome 64-way

Superdome 64-way

Superdome 64-way

SPU Product Number

SPU Product Number

SPU Product Number

SPU Product Number

A6113A

A5201A

A5201A+A5202A

TPC-C disclosure

TPC-C disclosure

TPC-C disclosure

TPC-C disclosure
(HP-UX)

N/A

N/A

TBD

TPC-C disclosure

TPC-C disclosure

TPC-C disclosure

TPC-C disclosure (Windows) N/A

N/A

707,102 tpmC
(Windows Server 2003
Datacenter Edition with SQL
Server 2000 (64-bit version)

Number of CPUs

Number of CPUs

Number of CPUs

Number of CPUs

2-16

2-32

6-64

Itanium 2 Processor

Itanium 2 Processor

Itanium 2 Processor

Itanium 2 Processor

1.5 GHz, 6 MB cache

1.5 GHz, 6 MB cache

1.5 GHz, 6 MB cache

Memory

Memory

Memory

Memory (with 512 MB or 1 GB
DIMMs)

2-128 GB

2-256 GB

6-512 GB

2-way or 4-way Cells

2-way or 4-way Cells

2-way or 4-way Cells

2-way or 4-way Cells

1-4

1-8

3-16

12-slot PCI-X I/O chassis

12-slot PCI-X I/O chassis

12-slot PCI-X I/O chassis

12-slot PCI-X I/O chassis

NOTE:

NOTE:

NOTE:

NOTE: SPU cabinet must be
filled first before placing I/O
chassis in I/O expansion
cabinet

1-4

No I/O expansion cabinet
required.

1-8

I/O expansion cabinet
required if number of I/O
chassis is greater than 4.

1-16

I/O expansion cabinet
required if number of I/O
chassis is greater than 8. A
second I/O expansion
cabinet is required if the
number of I/O chassis is
greater than 14.

Number of Partitions

Number of Partitions

Number of Partitions

Number of Partitions
without I/O expansion

without I/O expansion

without I/O expansion

without I/O expansion
cabinet

cabinet

cabinet

cabinet

1-4

1-4

1-8

Number of Partitions with

Number of Partitions with

Number of Partitions with

Number of Partitions with
I/O expansion cabinet

I/O expansion cabinet

I/O expansion cabinet

I/O expansion cabinet

N/A

1-8

1-16

HP-UX revision

HP-UX revision

HP-UX revision

HP-UX revision

HP- UX 11i version 2: August 2003

Windows revision

Windows revision

Windows revision

Windows revision

Windows Server 2003, Datacenter edition for Itanium 2; 2 4 months after

HP-UX ship release

Linux revision

Linux revision

Linux revision

Linux revision

Red Hat Enterprise Linux AS 3: December 2003; Debian Linux: TBD

RS-232C Serial Ports

RS-232C Serial Ports

RS-232C Serial Ports

RS-232C Serial Ports

Y

Y

Y

10/100Base-T Ethernet

10/100Base-T Ethernet

10/100Base-T Ethernet

10/100Base-T Ethernet

Y

Y

Y

DIMM Density

DIMM Density

DIMM Density

DIMM Density (MB)

512/1024

512/1024

512/1024

Site planning and

Site planning and

Site planning and

Site planning and
installation included

installation included

installation included

installation included

Y

Y

Y

Maximum Heat

Maximum Heat

Maximum Heat

Maximum Heat
dissipation

dissipation

dissipation

dissipation (BTUs/hour)

28,969

41,614

83,288

Typical Heat dissipation

Typical Heat dissipation

Typical Heat dissipation

Typical Heat dissipation
(BTUs/hour)

20,131

33,439

66,877

Depth

Depth

Depth

Depth (in/mm)

48.03/1,220

48.03/1,220

48.03/1,220

Width

Width

Width

Width (in/mm)

30/762

30/762

60/1,524

Height

Height

Height

Height (in/mm)

77.16/1,960

77.16/1,960

77.16/1,960

Weight

Weight

Weight

Weight (lbs/kg)

1102.31/500

1318.36/598

2636.73/1,196

Electrical Characteristics

Electrical Characteristics

Electrical Characteristics

Electrical Characteristics

AC input power-Option 7: 3
phase 5 wire input

200 240 VAC phase to neutral, 5 wire, 50/60 Hz

AC input power-Option 6: 3
phase 4 wire input

200 240 VAC phase to phase, 4 wire, 50/60 Hz

Current requirements at 220V-
240V

Option 7:

24 A

24 A

24 A

QuickSpecs

HP Integrity Superdome Servers: 16-way, 32-way,

HP Integrity Superdome Servers: 16-way, 32-way,

HP Integrity Superdome Servers: 16-way, 32-way,

HP Integrity Superdome Servers: 16-way, 32-way,

and 64-way

and 64-way

and 64-way

and 64-way

TechSpecs

DA - 11717 Worldwide — Version 1 — June 30, 2003

Page 32