beautypg.com

Quickspecs, Hp integrity superdome servers: 16-way, 32-way, And 64-way – HP Integrity Superdome Server User Manual

Page 20: And 64-way configuration

background image

The APC SL20KFB2 provides unparalleled power conditioning with its Delta-Conversion on- line double conversion
technology. This is especially helpful in regions were power is unstable.

Continuous Power during Short Interruptions of Input Power

Continuous Power during Short Interruptions of Input Power

Continuous Power during Short Interruptions of Input Power

Continuous Power during Short Interruptions of Input Power
The APC SL20KFB2 will provide battery backup to allow for continuous power to the connected equipment in the event of a
brief interruption in the input power to the UPS. Transaction activity will continue during brief power outage periods as long
as qualified UPS units are used to provide backup power to the SPU, the Expansion Modules, and all disk and disk array
products.

UPS Configuration Guidelines

UPS Configuration Guidelines

UPS Configuration Guidelines

UPS Configuration Guidelines
In general, the sum of the "Watt rating for UPS sizing" for all of the connected equipment should not exceed the watt rating
of the UPS from which they all draw power. In previous configuration guides, this variable was called the "VA rating for UPS
sizing." With Unity Power Factor, the Watt rating was the same as the kVA rating, so it didn't matter which one we used. VA is
calculated by multiplying the voltage times the current. Watts, which is a measurement of true power, may be less than VA if
the current and voltage are not in phase. APC SL20KFB2 has Unity Power Factory correction, so the kW rating equals the
kVA rating. Be sure to add in the needs for the other peripherals and connected equipment. When sizing the UPS, allow for
future growth as well. If the configuration guide or data sheet of the equipment you want to protect gives a VA rating, use
this as the watt rating. If the UPS does not provide enough power for the additional devices such as system console and mass
storage devices, additional UPSs may be required.

Superdome

Superdome

Superdome

Superdome
The only qualified UPS available for use with Superdome is the APC SL20KFB2 Silcon 3 Phase 20-kW UPS.
The APC SL20KFB2 can provide power protection for the SPU and peripherals. If the system console and primary mass
storage devices also require power protection (which is highly recommended) they may require one or more additional UPSs
depending on the total Watts. Make sure that the total watts do not exceed the UPS's voltage rating.

Integration/Installation

Integration/Installation

Integration/Installation

Integration/Installation
The APC SL20KFB2 includes both field integration start up service and next day on site service for one year provide by APC.

Power Connections with the APC SL20KFB2

Power Connections with the APC SL20KFB2

Power Connections with the APC SL20KFB2

Power Connections with the APC SL20KFB2

Product Number

Product Number

Product Number

Product Number

Watts

Watts

Watts

Watts

NOM Out

NOM Out

NOM Out

NOM Out

Output Receptacles

Output Receptacles

Output Receptacles

Output Receptacles Input Receptacles

Input Receptacles

Input Receptacles

Input Receptacles

SL20KFB2

20 kW

115/200 3PH, 120/208
3PH, 127/220 3PHV

Hardwire

Hardwire

Communications Connections

Communications Connections

Communications Connections

Communications Connections
A DB-25 RS-232 Contact Closure connection is standard on all APC SL20KFB2 UPS. A WEB/SNMP card is also included.

Power Management

Power Management

Power Management

Power Management

Description

Description

Description

Description

Network interface cards that provide standards-based remote management of UPSs

General Features

General Features

General Features

General Features

Boot-P support, Built-in Web/SNMP management, Event logging, Flash Upgradeable,
MD5 Authentication Security, Password Security, SNMP Management, Telnet Management,
Web Management

Includes

Includes

Includes

Includes

CD with software, User Manual

Documentation

Documentation

Documentation

Documentation

User Manual
Installation Guide

Type of UPSs

Type of UPSs

Type of UPSs

Type of UPSs

Some customers may experience chronic "brown-out" situations or have power sources that are consistently at the lower
spectrum of the standard voltage range. For example, the AC power may come in consistently at
92 VAC in a 110 VAC area. Heavy-load electrical equipment or power rationing are some of the reasons these situations
arise. The APC SL20KFB2 units are designed to kick in before the AC power drops below the operating range of the HP
Superdome Enterprise Server. Therefore, these UPS units may run on battery frequently if the AC power source consistently dips
below the threshold voltage. This may result in frequent

system shutdowns and will eventually wear out the battery. Although the on-line units can compensate for the AC power
shortfall, the battery life may be shortened. The best solution is to use a good quality boost transformer to "correct" the power
source before it enters the UPS unit.

QuickSpecs

HP Integrity Superdome Servers: 16-way, 32-way,

HP Integrity Superdome Servers: 16-way, 32-way,

HP Integrity Superdome Servers: 16-way, 32-way,

HP Integrity Superdome Servers: 16-way, 32-way,

and 64-way

and 64-way

and 64-way

and 64-way

Configuration

DA - 11717 Worldwide — Version 1 — June 30, 2003

Page 20