Henny Penny EEE-143 User Manual
Page 61
Model EEE-141,142, 143, 144
7-2. ERROR CODES
DISPLAY
CAUSE
CORRECTION
“E-21”
Slow heat recovery
Have a certified service technician check the fryer for correct
voltage to the unit; have the contactors and heating element
checked; have unit checked for loose or burnt wires
“E-22” “NO HEAT” Elements not
Check power cord and heat circuit
“CHECK PWR
heating
CORD AND
BREAKER”
“E-31”
Elements are up
Lower elements completely back into the vat
“E-41”, “E-46”
Programming
Turn switch to OFF, then back to ON; if display shows any
failure
of these error codes, have the controls re-initialized; if error code
persists, have the control board replaced
“E-47”
Analog converter
Turn switch to OFF, then back to ON; if “E-47” persists,
chip or 12 volt
have the I/O board, or the PC board replaced; if speaker
supply failure
tones are quiet, probably I/O board failure; have the I/O board
replaced
“E-48”
Input system
Turn switch to OFF, then back to ON; have controlPC board
error
replaced if “E-48” persists
“E-54C”
Temperature input
Turn switch to OFF, then back to ON; have control PC board
error
replaced if “E-54C” persists
“E-60”
AIF PC board not
Press power button to vat off and back on again if “E-60”
communicating with
persists, have the connector between the PC boards checked;
control PC board
replace AIF PC board or control PC board if necessary
7-4