Henny Penny EEE-143 User Manual
Page 41
Model EEE-141,142, 143, 144
2. LAST LOAD (Information on recent cook cycles)
Press and “2. LAST LOAD” show in displays.
Press a timer button or
for the product you want to
view the cook data and the LED flashes.
Press
button to start viewing the cook data.
For example, if the left LED is flashing, “PRODUCT FRY
L1” show in displays.
If the right
LED is flashing, “PRODUCT FRY R2” show in
displays.
Press
button to start viewing the cook data.
4-1. INFORMATION MODE
DETAILS (Continued)
FUNCTION DISPLAY EX:
Product (Last product cooked)
PRODUCT
FRY L1
Time of day the last Cook Cycle was started
STARTED FEB 4 2:25P
Actual Elapsed cook Time (Real seconds)
ACTUAL TIME
1:06
Programmed cook Time
PROG TIME
1:00
Max Temp during Cook Cycle
MAX TEMP
350°F
Min Temp during Cook Cycle
MIN TEMP
313°F
Avg Temp during Cook Cycle
AVG TEMP
322°F
Heat On (percentage) during Cook Cycle
HEAT ON
45%
Ready? (Was fryer Ready before start?)
READY?
YES
When Cook Cycle was stopped:
Early
QUIT AT
0:10 REM
OR
After complete Cook Cycle
*DONE*
+6 SEC
Difference (%) between actual and
ACT/PROG
1%
programmed cook time
109
4-2