beautypg.com

4 setting rs-485 parameters – EverFocus HDCCTV 12X IP66 SPEED DOME EPH5212 User Manual

Page 10

background image

10

Issue: 1.0

2.4 Setting RS-485 Parameters

The device can communicate with external controllers and DVRs by setting the Rotary switches and Dip switches.

Refer to the tables below for setting the dome camera ID and protocol. Total length of the cable for communication

should not exceed 1km.

2.4.1 Setting the address (ID) of dome camera

To prevent incorrect operation or malfunction, each dome camera must have a unique address (ID).

The default setting is 0. This corresponds to EVF-1 & Pelco-P ID 00 and Pelco-D ID 01.


Dome Camera ID Setting (Rotary Switch, SW301, SW302)

X10

X1

SW301

SW302

2.4.2 Setting the analog video format and RS-485 protocol

Analog Composite Video (Dip Switch, SW303)

No1

Baud Rate(bps)

Off

NTSC

ON

PAL

Dome Camera Protocol Setting (Dip Switch, SW303)

No2

Protocol

Off

Pelco D/P

ON

Others(Pelco P/ EVF-1)

Dome Camera Baud Rate Setting (Dip Switch,

SW303)

No3

No4

Baud Rate(bps)

Off

Off

2400

Off

On

4800

On

Off

9600

On

On

38400

Dome Camera Termination Setting Off/ON (NO5, Dip Switch, SW303)