Four-Wire Direct Wire

A 4-wire connection is required for

all mobile and manufactured home

installations, as well as all new

construction after January 1, 1996.

A UL-listed strain relief is required.

Use UL-listed 4-wire #10 AWG-

minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) of wire to

allow for removal and reinstallation of

the dryer.

1

Remove 5-inch (12.7 cm) of the outer covering

from the wire. Remove 5-inch of insulation from

the ground wire. Cut off approximately 1.5-inch

(3.8 cm) from the other three wires and strip 1

inch (2.5 cm) insulation from each wire. Bend

the ends of the three shorter wires into a hook

shape.

1" (2.5 cm)

Ground Wire

5" (12.7 cm)

2

Remove the terminal block access cover on the

upper back of the dryer.

3

Install a UL-listed strain relief into the power

cord through-hole.

4

Thread the 4-wire #10 AWG-minimum copper

power cable prepared in step 1 through the

strain relief.

Terminal Block

UL-Listed Strain Relief

UL-Listed 4-Wire Power

Cord

5

Transfer the dryer’s ground wire from behind the

green ground screw to the center screw of the

terminal block.

6

Attach the two hot leads of the power cord to the

outer terminal block screws.

7

Attach the white neutral wire to the center screw

of the terminal block.

8

Attach the power cord ground wire to the green

ground screw.

9

Tighten all screws securely.

10

Reinstall the terminal block access cover.

Hot (Black)

Ground Screw

Power Cord Ground

Wire

White Wire moved from

Ground Screw

Hot (Red)

Neutral (White)