INSTALLATION

NOTE

• In the Commonwealth of Massachusetts: This

product must be installed by a licensed plumber

or gas fitter. When using ball-type gas shut off

valves, they shall be T-handle-type. A flexible gas

connector, when used, must not exceed 3 feet.

This dryer is configured from the factory for natural

gas (NG). If the dryer is to be used with propane

(LP) gas, it must be converted by a qualified service

technician.

1

Make sure that the gas supply to the laundry

room is turned OFF and the dryer is unplugged.

Confirm that the type of gas available in your

laundry room is appropriate for the dryer.

2

Remove the shipping cap from the gas fitting at

the back of the dryer. Be careful not to damage

the threads of the gas connector when removing

the shipping cap.

3

Connect the dryer to your laundry room’s gas

supply using a new flexible stainless steel

connector with a 3/8-inch NPT fitting.

NOTE

• DO NOT use old connectors.

4

Securely tighten all connections between the

dryer and your laundry room’s gas supply.

5

Turn on your laundry room’s gas supply.

6

Check all pipe connections (both internal and

external) for gas leaks with a noncorrosive leak-

detection fluid.

7

Proceed to Venting the Dryer.

3/8" NPT gas

Connection

AGA/CSA-Certified

Stainless Steel Flexible

Connector

Gas Supply Shutoff

Valve

1/8" NPT Pipe Plug

High-Altitude Installations

The BTU rating of this dryer is AGA-certified for

elevations below 10,000 feet.
If your gas dryer is being installed at an elevation

above 10,000 feet, it must be derated by a qualified

technician or gas supplier.