beautypg.com

Leak testing instructions, Stop – Prestige Napoleon Prestige Series 500 Series 66 Inch Freestanding Grill Owner's Guide User Manual

Page 43

background image

43

www.napoleongrills.com

N415-0518 JAN 02.19

PROPANE

NATURAL

Leak Testing Instructions

WARNING!

A leak test must be performed annually and each time a cylinder is hooked up or if a

part of the gas system is replaced.

WARNING!

Never use an open flame to check for gas leaks. Be certain no sparks or open flames

are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,

damage to property, serious bodily injury, or death.

Leak testing

: This must be done before initial use, annually, and whenever any gas components are

replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak

Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,

hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one

recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified

gas installer.
If the leak cannot be stopped,

immediately shut off the gas supply

, disconnect it, and have the grill

inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.

X

STOP

!

!

N415-0518 JAN 02.19.indd 43

1/2/2019 12:11:35 PM