beautypg.com

Maintenance instructions, 14 en, Warning – Prestige Napoleon Prestige Series 500 Series 66 Inch Freestanding Grill Owner's Guide User Manual

Page 14

background image

14

EN

www.napoleongrills.com

N415-0518 JAN 02.19

WARNING!

Always wear protective gloves and safety glasses when cleaning your grill.

WARNING!

Turn off the gas at the source and disconnect the unit before servicing. To avoid

the pos

sibility of burns, maintenance should be done only when the grill is cool. A leak test must be

performed annually and whenever any component of the gas train is replaced or gas smell is present.

Maintenance Instructions

We recommend this gas grill be thoroughly inspected and serviced annually by a qualified service person.
At all times keep the gas grill area free from combustible materials, gasoline and other flammable vapors

and liquids. Do not obstruct the flow of ventilation and combustion air. Keep the cylinder enclosure

ventilation openings (located on the cart sides and at the front and back of the bottom shelf) free and

clear from debris.

Combustion Air Adjustment

: (This must be done by a qualified gas installer.) The air shutter is factory set

and should not need adjusting under normal conditions. Under extreme field conditions, adjustments

might be required. When the air shutter is adjusted correctly the flames will be dark blue, tipped with

light blue and occasionally yellow.

• With too little air flow to the burner, the flames are lazy yellow and can produce soot.
• With too much air flow, the flames lift erratically and can cause difficulties when lighting.

Adjusting the air shutter

:

1. Remove cooking grids and sear plates and leave lid open. You may have to open the door or remove

the top drawer (if equipped) to access the air-shutter screw located at the mouth of the burner. The back

cover must be removed for rear tube burner air shutter adjustment.
2. Loosen air-shutter lock screw and open or close air shutter as required. The normal opening settings

are:
Main Tube Burner

Propane 1/2″ (13mm) Rear Tube Burner

Propane Full Open

Natural 3/8″ (10mm)

Natural 1/8″ (3mm)

*Infra-Red burners have no air adjustment.

3. Light the burners and set to high. Visually inspect burner flames. When the shutters are set correctly,

turn burners off, tighten locking screws, and replace removed parts. Ensure that the insect screens are

installed.

Light Blue

Yellow Tipping

Dark Blue

Burner

Burner Port

Approximately

1/2” (13mm)

Cleaning The Outer Grill Surface:

Do not use abrasive cleaners or steel wool on any painted, porcelain or

stainless steel parts of your Napoleon Grill. Doing so will scratch the finish. Exterior grill surfaces should be

cleaned with warm soapy water while the metal is still warm to the touch. To clean stainless surfaces, use

a stainless steel or a non-abrasive cleaner. Always wipe in the direction of the grain. Over time, stainless

steel parts discolor when heated, usually to a golden or brown hue. This discoloration is normal and does

not affect the performance of the grill. Porcelain enamel components must be handled with additional

care. The baked-on enamel finish is glass-like, and will chip if struck. Touch-up enamel is available from

your Napoleon Grill dealer.

!

N415-0518 JAN 02.19.indd 14

1/2/2019 12:10:56 PM