beautypg.com

Using the grill, Caution, Lighting instructions – DCS Use & Care Guide User Manual

Page 24: Warning

background image

22

TO LIGHT THE GRILL BURNER:

Open the grill lid and/or remove the top grate cover from side burner (for 48BQR) before lighting. Turn all knobs to “OFF”.

Turn the main gas supply on. If you smell gas, shut-off gas supply and call for service.

Grill Lighting Instructions:

The grill knob is connected to the electronic ignition module. Pushing in on the burner knob will activate the igni-

tion module to get a spark.Push in and turn the selected burner knob to HI/SEAR position. Release the knob when

the burner lights. If burner does not light in 4 to 5 seconds, turn

knob “OFF” and wait 5 minutes before trying again so any accumu-

lated gas may dissipate.

Grill Match Lighting:

If the burner will not light after several attempts, then the burner

can be match lit. If you’ve just attempted to light the burner with

the ignition, allow 5 minutes for any accumulated gas to dissipate.

Keep your face as far away from the outdoor appliance as possible

and hold a paper book match over the hole located on the top left

for burner on the left, or the right hole for the right burner (Fig. 26 and Fig. 27). Push and turn the control knob

which is centered on the burner where the lit match is located, to “SEAR”. If the burner does not light in 4 seconds,

turn the knob off, wait 5 minutes and try again.

NOTE:

Improper lighting procedures can cause the LP tank flow control to activate, resulting in reduced heat output. If this is sus-

pected, to reset flow control, shut off all burner controls and LP cylinder valve, wait 30 seconds, then turn LP cylinder valve

on extremely slowly, wait five (5) seconds and push and hold the ignition

button and turn burner valve on to “SEAR”.

TO LIGHT DUAL SIDE BURNERS (48BQR MODELS ONLY):

CAUTION!

The side burner cover may be hot if the grill burners are in operation.

Side Burners Lighting Instructions:

First remove the burner cover and any cooking utensils from the

burner grate. The control knob is connected to the electronic igni-

tion module. Pushing in on the control knob will activate the igni-

tion module to get a spark. Push the control knob in and turn to

“HI”. If burner does not light in 4 to 5 seconds, turn knob “OFF” and

wait 5 minutes before trying again for any accumulated gas to dissipate. If

the burner will not light after several attempts, check the trouble shooting

instructions on page 33.

Side Burners Match Lighting:

Hold a lit paper book match near the burner ports, turn the control knob

counterclockwise to “HI”. Move your hand immediately once the burner is

lit. Rotate the control knob to the desired setting.

Note:

If you are using propane gas, a slight pop or flash may occur at the burner

ports a few seconds after the burner has been turned “off”. This “extinction pop” is

normal for propane gas.

Side burners:

Your side burner is equipped with burners typical of those used in restaurants. These

burners are designed for maximum cleanability and controlability. The burner should

never be operated if the cap is not in place (Fig. 29).

USING THE GRILL

LIGHTING INSTRUCTIONS

FIG. 26

FIG. 27

FIG. 28

FIG. 29

Cap

Control Knobs

SEAR

OFF

All knobs must be in the OFF position before
opening LP tank valve.

Now open the LP tank valve two (2) full
turns min.

Failure to follow the steps in the order shown may cause the Flow

Limiting Device to activate resulting in extremely low gas flow and

improper operation.

Attach regulator hose assembly to tank.

WARNING

3

1

2