beautypg.com

Installation, Gas hook-up – DCS Use & Care Guide User Manual

Page 18

background image

16

INSTALLATION

GAS HOOK-UP

LP TANK RESTRAINT FOR BUILT-IN INSTALLATION

If the grill is to be installed in a Built-in application, then the grill must be installed in accordance with the

Built–in installation guidelines.

The gas connector must comply with the Standard for Connectors for Outdoor Gas Appliances & Manufactured

Homes, ANSI Z21.75/ CSA 6.27. The connection must be no longer than 6’ (1820mm) in length and be suitable for

outdoor installation.

If you intend to operate your Built-in grill on LP gas utilizing a 20v lb Type 1 cylinder, then the Built-in LP tank

restraint must be installed prior to initial use of the grill. If you do not have one please contact DCS Customer Care

at (888) 936-7872 for information on obtaining one.

The following steps will illustrate how to properly locate and install the LP tank restraint within the Built-in enclo-

sure.

NOTE:

The grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire grill

system, is leak tested.
Do not remove the Regulator/Hose assembly from the grill during installation.

Note:
Gas piping and connectors must be clamped within the the enclosure to avoid contact with moving parts and hot sur-

faces. Where the gas piping passes through an opening in the enclosure, the piping must be protected for a distance of at

least 2” (50 mm) either side of the opening.

FIG. 10

18” (45,7cm) max.

The

maximum

distance from the center

of the manifold cut out to the center of

the tank restraint is

18 inches (45,7cm)

.

Center of manifold cut

out projected to floor

of the island.

Center of Tank Restraint must be placed

within this area to avoid causing stress

on the LP regulator hose connection.

The connection must be visible to the