Installation, Gas hook-up, Gas requirements – DCS Use & Care Guide User Manual

Page 16: Natural gas hook up, Lp gas hook up (type 1 or qcc1 regula- tor)

background image

14

GAS REQUIREMENTS

Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating

plate agrees with that of the supply. The rating plate is located on the underside of the drip tray. Never connect

an unregulated gas line to the appliance. You must use the gas regulator provided with the unit, even if the sup-

ply is controlled.

An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied

parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA

70 or the Canadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CSA-B149.1 Natural

Gas Installation Code or CSA-B149.2 Propane Installation Code.

All pipe sealants must be an ap proved type and resistant to the actions of LP gases. Never use pipe sealant on

flare fittings. All gas connections should be made by a qualified technician and in accordance with local codes

and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code

ANSI Z223.1. Gas conversion kits are available from Customer care. When ordering gas conversion kits, have the

model number, and the type of gas (natural or LP) from your grill.

TOTAL GAS CONSUMPTION OF THE GRILL WITH ALL BURNERS ON HI:

BGC48-BQR - 126,500 Btu/hr or 133.5MJ/h BGC48-BQAR - 121,500 Btu/hr or 128.2 MJ/h

BGC36-BQAR - 92,500 Btu/hr or 97.5 MJ/h

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.) The appliance must be isolat-

ed from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing

of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation of this

appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI

Z223.1/NFPA 54. Installation in Can ada must be in accordance with Natural Gas and Propane Installation Code,

CSA B149.1, and/or Propane Storage and Handling Code, B149.2 and local codes.

NATURAL GAS HOOK UP:

(THIS TYPE OF CON-

NECTION SHOULD BE PERFORMED BY A CERTIFIED

OR LICENSED TECHNICIAN ONLY.)

Connection:

1/2” NPT female with 3/8” flare adapter.

Operating pressure:

4.0” W.C.

Supply pressure:

5” to 14”

water column. If in excess of 14” W.C., a step down regula-

tor is required. Check with your local gas utility company

or local codes for instructions on installing gas supply

lines. Be sure to check on type and size of run, and how

deep to bury the line. If the gas line is too small, the grill

will not function properly. Any joint sealant used must

be an approved type and be resistive to the actions of LP

gases.

TO HOOK-UP THE FITTINGS SUPPLIED WITH

THE GRILL:

Assemble as shown (Fig. 08). Use threading compound

on male threads only. Do not use threading compound

on the male end of the 1/2 NPT to 3/8 flare adapter. Use

a second pipe wrench to hold the grill inlet pipe to avoid

shifting any internal gas lines of the grill. Ensure that the

regulator arrow points in the direction of gas flow towards

the unit, away from the supply. Do not forget to place the

installer-supplied gas valve in an accessible location.

LP GAS HOOK UP (TYPE 1 OR QCC1 REGULA-

TOR):

Grills orificed for use with LP gas come equipped with a high capacity hose/regulator assem bly for connection to

a standard 20 lb. LP cylinder (Type 1). The LP tank is not included.

*Installation must conform with

local codes or with the National

Fuel Gas Code ANSI Z223.1 or

the CSA-B149.2 Propane

Installation Code

Coupling

1/2” NPT x

2.0”

NIpple

Regulator

4.0" W.C.

Adapter 1/2” NPT

to 3/8” flare fitting

Do not put threading

compound on these

threads

Bottom of unit

Threading compound

must be resistant to LP gas

1/2” NPT x 5.0"

Nipple

Installer supplied shut-off

valve must be easily

accessible*

FIG. 08 Natural Gas

INSTALLATION

GAS HOOK-UP