beautypg.com

Elation Professional Design Spot 250 Pro User Manual

Page 46

background image


Design Spot 250 Pro™

©Elation Professional® 46 Design Spot 250 Pro™

defective motor IC drive on the main PCB).

05Er - Color-wheel error:

The color wheel is not located in the default position after start-up or after a reset command.

This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit

malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure

(defective motor or a defective motor IC drive on the main PCB).

06Er - Rotating gobo-wheel error:

The gobo-wheel is not located in the default position after start-up or after a reset command.

This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit

malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure

(defective motor or a defective motor IC drive on the main PCB).

07Er - Rotating gobo indexing error:

The gobo is not located in the default position after start-up or after a reset command. This

message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit

malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure

(defective motor or a defective motor IC drive on the main PCB).

08Er - Fix Gobo-wheel error

This message will appear after the reset of the fixture if the magnetic-indexing circuit

malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive

circuit on the main PCB). The fix gobo wheel is not located in the default position after the

reset.

09Er - Prism-wheel error

This message will appear after the reset of the fixture and if the magnetic-indexing circuit

malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its

driver circuit on the main PCB). The Prism wheel is not located in the default position after

the reset.

10Er - Focus-error

This message will appear after the reset of the fixture and if the magnetic indexing circuit