Events screen, Event list, Scheduled events – Ashly mXa-1502 12-Channel 4-Zone DSP Mixer-Amplifier User Manual
Page 31: Triggered events, Diagnostics screen

6.4
Events
Events can be scheduled using the internal
real-time-clock (RTC), or triggered by a logic
input connected to rear panel Trigger Input
1-8. Multiple actions can be included in a single
event, and a delay time can be added after
each action as the event sequence is executed.
Use the New Event command to create events.
Events can also be cloned, edited, and deleted.
Events > Event List
All programmed events, scheduled or
triggered, are listed here by event name, event
type, and event actions. Click on any event in
the list to test, clone, edit, or delete that event.
New events can be added from this screen.
Events > Scheduled Events
Scheduled events are programmed and saved
within the unit, then executed based on the real
time clock. Events can be scheduled for one
time, daily, weekly, or yearly.
Several actions can be grouped together in
sequence, but still be part of a single scheduled
event. A delay time up to 99 seconds can be
inserted after each individual action within the
sequence.
Scheduled event action types include the
following:
•
Cancel Today's Events - over-rides all other
scheduled events for the day, ending at
midnight.
•
Channel Mute - Mutes selected input or
output channels, but does not mute mixers
•
GPO High - Sets GPO pin 1 or pin 2 to logic
high
•
GPO Low - Sets GPO pin 1 or pin 2 to logic low
•
Gain Decrement - Sets the value of - gain
change for all selected input or output
channels
•
Gain Increment - Sets the value of + gain
change for all selected input or output
channels
•
Mixer Mute - Mutes selected mixer
channels, but does not mute input or output
channels
•
Power On - Turns the amplifier on
•
Preset Recall - Recalls one preset from
device memory
•
Source Select - Sets designated input
channels for one or all four mixers
•
Standby - Puts the unit in standby mode
•
Sub Preset Recall - Recalls one sub-preset
from memory
Events > Triggered Events
Triggered events are assigned to one of eight
rear panel trigger input pins. The event is
triggered when the input pin is connected to
the ground pin.
Triggered event action types include the
following:
•
A/B Source Select - For each or all four
selected mixers, this toggles between two
sets of selected input channels
•
Action Sequence - Select multiple actions
for one event trigger. Delay time can be
added following each action
•
Channel Mute - Mutes selected input or
output channels, but does not mute mixers
•
General Purpose Output Toggle - Toggles
the logic output state of selected general
purpose output 1 or 2
•
Mixer Mute - Mutes selected mixer
channels, but does not mute input or output
channels
•
Paging - Selects one channel to be used
as a paging input, also selects one or more
mixers to apply the paging input t
•
Pause/Resume Schedules - Interrupts
scheduled events, resumes scheduled
events when open
•
Power On/Off - Toggles between power on
and power off
•
Preset Toggle - Toggles between two
selected presets
6.5
Diagnostics
Diagnostics monitor and record a log of
selected activity, useful for debugging system
issues or viewing user activity. The log can be
exported as *.csv file.
The log feature can monitor and record the
following activity categories, and can display
results within a specified date range.
- Status
- Operation
- Events
- Presets
- Security
- Network
31
mXa-1502 • Operating Manual
Ashly AquaControl™ Software