Installation and operation, cont’d – Extron Electronics RGB 201 User Manual
Page 26

RGB 201 Rxi Universal Interface • Installation and Operation
Installation and Operation, cont’d
2-14
Up
— The interface outputs serration pulses in the vertical
sync interval.
Down
— The interface does not output serration pulses.
4 — Vertical sync pulse width
— For some digital displays, if:
•
no picture appears,
•
the picture cuts in and out,
•
the picture is scrambled,
try adjusting the output vertical sync pulse width or
switching from ADSP to DDSP.
Up
— The vertical sync pulse is narrow.
Down
— The vertical sync pulse is wide.
5 — Monaural audio left
Up
— Mono audio is output on the left channel only.
Down
— Normal stereo output.
6 — No LCD backlight
— This switch controls illumination of
the LCD backlight.
Up
— The LCD backlight is off, except for three seconds at
power-up.
Down
— The LCD backlight is on while a signal is present
at the selected input.
7 — Local monitor and ID bit termination
— This switch
controls input ID bit termination when no local monitor is
used.
Up
— ID bits 4 and 11 are tied to ground.
Down
— ID bits 4 and 11 are unterminated.
8 — Spare