Installation and Operation, cont’d

2-14

Up

— The interface outputs serration pulses in the vertical

sync interval.

Down

— The interface does not output serration pulses.

4 — Vertical sync pulse width

— For some digital displays, if:

no picture appears,

the picture cuts in and out,

the picture is scrambled,

try adjusting the output vertical sync pulse width or

switching from ADSP to DDSP.

Up

— The vertical sync pulse is narrow.

Down

— The vertical sync pulse is wide.

5 — Monaural audio left

Up

— Mono audio is output on the left channel only.

Down

— Normal stereo output.

6 — No LCD backlight

— This switch controls illumination of

the LCD backlight.

Up

— The LCD backlight is off, except for three seconds at

power-up.

Down

— The LCD backlight is on while a signal is present

at the selected input.

7 — Local monitor and ID bit termination

— This switch

controls input ID bit termination when no local monitor is

used.

Up

— ID bits 4 and 11 are tied to ground.

Down

— ID bits 4 and 11 are unterminated.

8 — Spare