ProSoft Technology MVI56E-GSC/ GSCXT User Manual
Page 25

MVI56E-GSC ♦ CompactLogix or MicroLogix Platform
Start Here
Enhanced Generic ASCII Serial Communication Module
User Manual
ProSoft Technology, Inc.
Page 25 of 140
May 9, 2014
2 On the D
OWNLOAD
dialog box, click B
ROWSE
D
EVICES
to open P
RO
S
OFT
D
ISCOVERY
S
ERVICE
.
3 Select the module, and then click the right mouse button to open a shortcut
menu. On the shortcut menu, choose S
ELECT FOR
PCB.
4 Close Prosoft Discovery Service.
5 Click D
OWNLOAD
to transfer the Ethernet configuration to the module.
Using CIPconnect
®
to Connect to the Module
You can use CIPconnect
®
to connect a PC to the ProSoft Technology MVI56E-
GSC module over Ethernet using Rockwell Automation’s 1756-ENBT
EtherNet/IP
®
module. This allows you to configure the MVI56E-GSC network
settings and view module diagnostics from a PC. RSLinx is not required when
you use CIPconnect. All you need are:
The IP addresses and slot numbers of any 1756-ENBT modules in the path
The slot number of the MVI56E-GSC in the destination ControlLogix chassis
(the last ENBTx and chassis in the path).
To use CIPconnect, follow these steps.
1 In the tree view in ProSoft Configuration Builder, right-click the MVI56E-GSC
icon to open a shortcut menu.