ProSoft Technology MVI56E-GSC/ GSCXT User Manual
Page 126

Reference
MVI56E-GSC ♦ CompactLogix or MicroLogix Platform
User Manual
Enhanced Generic ASCII Serial Communication Module
Page 126 of 140
ProSoft Technology, Inc.
May 9, 2014
1 On the Connected to Go Online dialog box, click the S
ELECT
F
ILE
button.
2 Choose the sample program file that matches your firmware version, and
then click the S
ELECT
button.
3 RSLogix will load the sample program.
The next step is to configure the correct controller type and slot number for your
application.
4.7.2 Choosing the Controller Type
The sample application is for a 1756-L63 ControlLogix 5563 Controller. If you are
using a different model of the ControlLogix processor, you must configure the
sample program to use the correct processor model.
1 In the Controller Organization list, select the folder for the controller and then
click the right mouse button to open a shortcut menu.
2 On the shortcut menu, choose P
ROPERTIES
.
This action opens the Controller
Properties dialog box.
3 Click the C
HANGE
T
YPE
or C
HANGE
C
ONTROLLER
button. This action opens
the Change Controller dialog box.