beautypg.com

ProSoft Technology PS69-DPM User Manual

Page 89

background image

PS69-DPM ♦ CompactLogix or MicroLogix Platform

Contents

PROFIBUS DPV1 Master

User Manual

ProSoft Technology, Inc.

Page 89 of 130

October 1, 2014

Failure

Significance

Error source

Help

17 =
CON_NA

No response of the station

Slave

Check network wiring, check bus address of
Slave or baud rate support

18 =
CON_DS

Master not into the logical token ring Network in general Check master DP address or highest-station-

address of other Masters. Examine bus wiring

for bus short circuits.

54 =

CON_AD

Negative response received, access

denied

Slave

access denied

MSAC1_Read and MSAC1_Write

Failure

Significance

Error source Help

0 = CON_OK

Service was executed without an
error

2 = CON_RR

Resource unavailable

Slave

Slave has no buffer space left for the
requested service

3 = CON_RS

Requested function of master is not
activated within the slave

Slave

Slave is not activated in its DPV1support

9 = CON_NR

No answer-data, although the slave
has to response with data

Slave

Slave has not sent any data back

17 = CON_NA

No response of the station

Slave

Check network wiring, check bus address of

Slave or baud rate support

18 = CON_DS

Master not into the logical token ring Network in

general

Check Master DP address or highest-station-
address of other Masters. Examine bus wiring

to bus short circuits

25 = CON_NP

No plausible reaction of remote
partner

Slave

Slave does not conform to DPV1 norm

54 = CON_AD

Negative response received, access

denied

Slave

Access denied to requested data. Check
Error_Code_1 and Error_Code_2 in response

message to get further error information


81 hex =
REJ_SE

DEVICE is about to stop the DPV1-
communication or the DPV1 is not in

OPEN state

HOST,
configuration

DPV1 communications must be configured to
be activated by the DEVICE

82 hex =
REJ_ABORT

DEVICE has stopped the DPV1
communication automatically

Slave

A previously addressed Slave has responded
with non conform parameters

83 hex =

REJ_PS

A previous service is still in process HOST

Wait for the outstanding answer first. Parallel

services are not allowed

84 hex =
REJ_LE

The length indicator msg.data_cnt
exceeds maximum configured size

HOST

Reduce length of message or enlarge
maximum buffer size in PROSOFT.fdt

(SYCON.net) or in SLAVE data set

85 hex = REJ_IV Wrong parameter in request

HOST

Check msg.function or msg.device_adr
parameter of requested message

9a hex =

REJ_COM

Unknown msg.b command

HOST

Correct the requested msg.b parameter of

message