5. Cable Connection Parameter

The wiring details are as below:

100FX Fiber Optical Cables:

Standard

Fiber Type

Cable Specification

100Base-FX (1300nm)

Multi-mode

50/125μm or 62.5/125μm

100Base-FX (1310nm)

Multi-mode

50/125μm or 62.5/125μm

Single-mode

9/125μm

100Base-BX-U
(TX: 1310/RX: 1550)

Single-mode

9/125μm

100Base-BX-D
(TX: 1550/RX: 1310)

1000X Fiber Optical Cables:

Standard

Fiber Type

Cable Specification

1000Base-SX (850nm)

Multi-mode

50/125μm or 62.5/125μm

1000Base-LX (1300nm)

Multi-mode

50/125μm or 62.5/125μm

Single-mode

9/125μm

Wiring Distances:

Standard

Fiber

Diameter
(micron)

Modal Bandwidth
(MHz * km)

Max. Distance
(meters)

1000Base- SX

MM

62.5
62.5
50
50

100
200
400
500

220
275
500
550

1000Base- LX

MM

62.5
50
50

5
4
5

550

SM

9

N/A

5000*

Note

The Single-mode port (1000Base-LX port) of IGTP-802TS,
IGTP-805AT is complied with LX 5 kilometers and provides
additional margin allowing for a 10/20/30/40/50/70/120