beautypg.com

In case of problems, In case of problems –5 – Avago Technologies AcceleRAID 170LP User Manual

Page 45

background image

Controller Start-up

Manual No. DB11-000024-00

3-5

In Case of Problems

If problems are encountered during start-up, check the following:

• Check SCSI cabling for loose connections, pin mismatches (make sure

pin 1 on the cable matches pin 1 on the connector), bent pins, and
damaged or crossed cables.

• Check cable length; this includes internal bus lengths in enclosures.

• Check termination.

• Check SCSI IDs on all drives.

• Check to see if any of the LED lights on the AcceleRAID 170LP

controller are on.

If the motherboard is PCI 2.2 compliant then at least one of these LED
lights will be on: D1, D2, D3, D4.

This manual is related to the following products: