Step 4. Connecting Drive Activity LED Indicators (Optional)

www.3ware.com

25

Figure 20. 24-Port 3ware 9650SE-24M8 Serial ATA RAID Controller

Additional Details About the LED Status

Connectors

As shown in Figure 16 through Figure 19, LED connectors for
individual drives are on J7 for the 2-port and 4-port cards, on J7 and
J8 for the 8-port, on J7, J8, and J9 for the 12-port cards, on J7, J8,
J9, and J1 for the 16 port card, and on J9, J10, J11, J12, J13, and J14
for the 24-port card.

Pin 1 is located in the lower left-hand corner of each 10-pin
connector. The odd-numbered pins, located on the bottom row, are
3.3V for the anode (+) side of each LED to be connected. The even-
numbered pins are on the top or cathode (-) side. Table 2
summarizes the LED indicator pin positions for the different
controllers.

Overall LED drive status indicator is the

right-most LED header pin pair on each

LED connector (J9, J10, J11, J12, J13,

J14). The anode is the lower of the two

pins and the cathode is the upper.

LED indicators for individual drives

J9 is for drives 0, 1, 2, 3 (left to right)

J10 is for drives 4, 5, 6, 7 (left to right)

J11 is for drives 8, 9, 10, 11 (left to right)

J12 is for drives 12, 13, 14, 15 (left to right)

J13 is for drives 16, 17, 18, 19 (left to right)

J14 is for drives 20, 21, 22, 23 (left to right)