5 safety characteristics – Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 39

LSI Corporation
- 39 -
12Gb/s MegaRAID SAS RAID Controllers User Guide
April 2014
Chapter 3: MegaRAID SAS RAID Controller Characteristics
Technical Specifications
3.3.4.8
Operating and Nonoperating Conditions for MegaRAID SAS 9380-8e RAID Controllers
For the MegaRAID SAS 9380-8e RAID controller, the operating (thermal and atmospheric) conditions are as follows:
Relative humidity range is 20 percent to 80 percent noncondensing
Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS3108 processor above the
maximum ambient temperature
Temperature range: 10 °C to +55 °C (with or without the CVFM04 module attached)
The parameters for the nonoperating (such as storage and transit) environment for these controllers are as follows:
Relative humidity range is 5 percent to 90 percent noncondensing.
Temperature range: –40 °C to +70 °C
3.3.5
Safety Characteristics
All 12Gb/s MegaRAID SATA+SAS RAID controllers meet or exceed the requirements of UL flammability rating 94 V0.
Each bare board is also marked with the supplier name or trademark, type, and UL flammability rating. For the boards
installed in a PCI Express bus slot, all voltages are lower than the SELV 42.4V limit.