Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other

combustible material other than wood flooring the appliance shall

be installed on a metal or wood panel extending the full width and

depth of the appliance.
The base referred to above does not mean the fire-proof base as

used on wood stoves. The protection is for rugs that are extremely

thick and light colored tile.

Solid-fuels shall not be burned in a masonry or UL 127 factory-

built fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment

or accessories and repair and servicing of equipment shall be

performed only by a qualified agency. The term "qualified agency"

means any individual, firm, corporation or company which either in

person or through a representative is engaged in and is responsible

for (a) the installation or replacement of gas piping or (b) the

connection, installation, repair or servicing of equipment, who is

experienced in such work, familiar with all precautions required

and has complied with all the requirements of the authority having

jurisdiction.

State of Massachusetts: The installation must be made by

a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental

room heaters shall provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.
In the Sate of Massachusetts, unvented propane and natural

gas-fired space heaters shall be prohibited in bedrooms and

bathrooms.

The installation must conform with local codes or, in the absence

of local codes, with the National Fuel Gas Code, International Fuel

Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 1430 Broadway,

New York, N.Y. 10018.

high Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be

reduced at the rate of 4 percent for each 1,000 feet (305m) above

sea level. Contact the manufacturer or your gas company before

changing spud/orifice size.
Well head gas Installations

Some natural gas utilities use "well head" gas. This may affect the

Btu output of the unit. Contact the gas company for the heating

value. Contact the manufacturer or your gas company before

changing spud/orifice size.

WARNINg: This appliance is equipped for (natural gas or

propane) gas. Field conversion is not permitted.

Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card supplied

with unvented room heater.

3. Installer should show owner how to start and operate unvented

room heater.

Always consult your local Building Department regarding

regulations, codes or ordinances which apply to the installation of

an unvented room heater.
This appliance may be installed in an aftermarket* manufactured

(mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from

the manufacturer.

This appliance is only for use with the type of gas indicated on

the rating plate. This appliance is not convertible for use with

other gases.

WARNING: ANY CHANGE TO THIS HEATER OR ITS

CONTROLS CAN BE DANGEROUS.

Improper installation or use of the heater can cause serious

injury or death from fire, burns, explosion or carbon

monoxide poisoning.

This series is design certified in accordance with American National

Standard Z21.11.2 by the Underweriters Laboratories, Inc. as an

Unvented Room Heater and should be installed according to these

instructions.
Any alteration of the original design, installed other than as

shown in these instructions or use with a type of gas not shown on

the rating plate is the responsibility of the person and company

making the change.
750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts

(electrical current) which energizes the magnet in the gas valve.

After 30 seconds to 1 minute time period you can release the gas

control knob and the pilot will stay ON. Allow your pilot flame to

operate an additional one (1) to two (2) minutes before you turn the

gas control knob from the PILOT position to the ON position. This

time period allows the millivolts (electrical energy) to build-up to

a sufficient level allowing the gas control to operate properly.
Important

All correspondence should refer to complete Model Number, Serial

Number and type of gas.
Attention: During initial use of ceramic log you will detect an

odor as the ceramic log is cured. Also, during the curing process

the ceramic log will burn with a yellow flame.
Notice:
During initial firing of this unit, its paint will bake out, and

smoke will occur. To prevent triggering of smoke alarms, ventilate

the room in which the unit is installed.