beautypg.com

Burner instructions – Empire Comfort Systems VFP36SP32EN-2 User Manual

Page 21

background image

26670-0-0110

Page 21

Check the following items during installation prior to

lighting the multisided burner:

• Check all carryover ports for blockage from the ceramic

media

o If there is blockage, use a small pointed tool to

move the ceramic media away from the carryover port.

• Check air shutter for correct setting.

o NAT gas – Air shutter 1/8" (3.2 mm) minimum

open

o LP gas – Air shutter full open

• For best results when lighting the burner, have your

adjustable flame knob to the HI position, then adjust to

a lower setting after the burner has ignited.

• When first lighting the pilot on the burner, it takes

approximately 60 to 75 seconds to fully heat and energize

the thermopile. Once the thermopile is energized, turn

on the gas valve and light the burner.

AIR SHUTTER
1/8” (3.2mm) OPEN

AIR SHUTTER

FULL OPEN

BURNER INSTRUCTIONS