Page 20

1. STOP! Read the safety information label.

2. Open bottom louver assembly.

3. Set REMOTE/OFF/ON switch to

"OFF."

4. Turn off all electric power to the

appliance (if applicable).

5. Push in gas control knob slightly

and turn clockwise

to

"OFF." NOTE: Knob cannot be

turned from "PILOT" to "OFF" unless knob

is pushed in slightly. Do not force.

6. Wait ten (10) minutes to clear out any gas.

Then smell for gas, including

near the floor. If you smell gas,

STOP! Follow "B" in the safety

information above. If you do not

smell gas, go to the next step.

7. Find pilot - Follow metal tube

from gas control. The pilot is

behind the burner on the right

side.

8. Turn gas control knob counterclockwise

to

"PILOT."

9. Push in control knob all the way and hold in. Repeatedly push

the Piezo Ignitor Button until the pilot is lit. Continue to hold

the control knob in for about one (1) minute after the pilot is

lit. Release knob, and it will pop back up. Pilot should remain

lit. If it goes out, repeat steps 5 through 9.

• If knob does not pop up when released, STOP and IM-

MEDIATELY call a qualified service technician or gas

supplier.

• If the pilot will not stay lit after several tries, turn the gas

control knob to "OFF" and call your service technician

or gas supplier.

10. Turn gas control knob counterclockwise

to "ON."

11. Set REMOTE/OFF/ON switch to desired setting.

12. Turn on all electric power to the appliance (if applicable).

13. Close bottom louver assembly.

A. This appliance has a pilot which must be lighted by

hand. When lighting the pilot, follow these instructions

exactly.

B. BEfORE LIghTINg smell all around the appliance area

for gas. Be sure to smell next to the floor because some

gas is heavier than air and will settle on the floor.

WhAT TO DO If yOU SMELL gAS

• Do not try to light any appliance.

• Do not touch any electrical switch;

Do not use any phone in your building.

• Immediately call your gas supplier from a neighbor's

phone. follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or turn

by hand, don't try to repair it; call a qualified service

technician. Force or attempted repair may result in a fire

or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect

the appliance and to replace any part of the control system

and any gas control which has been under water.

1. Open bottom louver assembly.

2. Set REMOTE/OFF/ON switch to "OFF."

3. Turn off all electric power to the appliance if service is to be

performed (if applicable).

4. Push in gas control knob slightly and turn clockwise

to "OFF." Do not force.

5. Close bottom louver assembly.

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE

(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE

(LPG)

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE

(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE

(LPG)

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE

(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE

(LPG)

MILLIvOLT vALvE LIghTINg INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

WARNINg: If you do not follow these instructions exactly, a fire or explosion may result caus-

ing property damage, personal injury or loss of life.