Whelen CANWC1 User Manual
Page 6
Page 6
CanTrol ID
4 (J1) - High Current Outputs
Pos.
J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J1-7
J1-8
Color
BRN
RED
ORG
YEL
GRN
BLU
VIO
GRY
1 (J2) - LED Outputs 17-32
Pos.
Output Color
J2-1
17
BRN
J2-2
18
RED
J2-3
19
ORG
J2-4
20
YEL
J2-5
21
WHT/BRN
J2-6
22
WHT/RED
J2-7
23
WHT/ORG
J2-8
24
WHT/YEL
J2-9
25
GRN
J2-10
26
BLU
J2-11
27
VIO
J2-12
28
GRY
J2-13
29
WHT/GRN
J2-14
30
WHT/BLU
J2-15
31
WHT/VIO
J2-16
32
WHT/GRY
2 (J4) - LED Outputs 1-16 + LC AUX 1, 2, 3
Pos. AUX
Color
Function*
J4-1
1
WHT/BLK
Horn Transfer Relay
J4-2
2
RED/WHT Unused
J4-11
3
WHT
Unused
J4-12
J4-13
9
GRN
J4-14
10
BLU
J4-15
11
VIO
J4-16
12
GRY
J4-17
13
WHT/GRN
J4-18
14
WHT/BLU
J4-19
15
WHT/VIO
J4-20
16
WHT/GRY
Pos. Output Color
J4-3
1
BRN
J4-4
2
RED
J4-5
3
ORG
J4-6
4
YEL
J4-7
5
WHT/BRN
J4-8
6
WHT/RED
J4-9
7
WHT/ORG
J4-10
8
WHT/YEL
- Not Used -
8 - PA Microphone Port
9 - MIC Volume Adjustment
10 - RAD Repeat Volume
6 - Siren Fuse
This port accepts a standard 1/4" Microphone
plug for PA functions. NOTE: If your system
uses the hand-held controller, this port should
not be used.
Used to set the PA broadcast level to the
desired volume (see text).
Used to set the PA broadcast level to the
desired volume (see text).
This fuse (20A) protects the
Siren Output
7 - Siren Speaker
Pos.
1
2
3
Description
Speaker (+)
Speaker (-)
Not Used
15 - USB Port
12 - WC Lightbar
Pos.
1
2
3
Description
CAN A
SHIELD
CAN B
Color
GRN
BARE
GRY
11 - Control Head
Used to connect the control
head to the
system
CanTrol
Used to connect a Windows™
based laptop or PC to the
System.
CanTrol
5 - Main Power
Pos.
1
2
3
4
Description
GND
+12VDC(Fuse @ 40A)
+12VDC
GND
(Fuse @ 40A)
3 (J10) - Traffic Advisor Outputs
Pos.
J10-1
J10-2
J10-4
J10-5
J10-3
J10-6
J10-7
J10-8
J10-9
J10-10
J10-11
J10-12
Description
(BRN) - T/A 1
(RED) - T/A 2
(ORG) - T/A 3
(YEL) - T/A 4
(GRN) - T/A 5
(BLU) - T/A 6
(VIO) - T/A 7
(GRY) - T/A 8
(WHT) - Comm. (+12V)
Not Used
Not Used
Not Used
14 - Diagnostic LEDs
ERR (Error) LED
WC (CanTrol Serial Data Bus) LED
POW (Power) Status LED
Steady
CanTrol Controller Bus is set to
OFF. Check Interface Box.
Off
No Error.
Single Flash
Bad CanTrol connection. Check
Lightbar I/O or Interface Box for
proper operation.
Double Flash
Error Control Event. Check
Lightbar I/O.
Steady
Good communication received
from Lightbar.
Off
Check Power LED;
If Off, turn on Controller.
If On, check connections
Fast Blink
Pre-operational State (Boot-up).
Single Flash
Bad
connection or
off. Check lightbar I/O or
Interface Box for proper operation.
Steady
system is On.
Off
system is Off.
CanTrol
CanTrol
CanTrol
CanTrol
13 (J17) - Logic Inputs
Pos.
Input
Color
Function*
J17-1
Logic 1
WHT/BRN
Horn Sense (Neg.)
J17-2
Logic 2
WHT/RED
Park Sense 1 (Neg.)
J17-3
Logic 3
WHT/ORG
Unused
J17-4
Logic 4
WHT/YEL
Unused
J17-9
Logic 5
BLK/WHT
Unused
J17-10 Logic 6
WHT/GRN
Unused
J17-11 Logic 7
WHT
Unused
J17-12 Logic 8
WHT/BLU
Unused
J17-5
Analog 1
WHT/BLK
Backlight
J17-13 Analog 2
WHT/GRY
Unused
J17-6
Analog 3
WHT/VIO
Unused
J17-7
Ign.Sense RED/WHT
Ignition
J17-8
Radio
BLU
Radio Repeat
J17-16 Radio
BLU
Radio Repeat
* These lists shows the default functions.
These functions can be changed using
the CanTrol™ configuration software
20
1
2
4
5
3
1 2 3
14
1
2
3
4
1 4 7
10
11
12
2 5 8
3 6 9
5
3
2
4
1
9
6 7 8
10 11 12 13 14 15 16
8
10
11
12
13
14
15
16
9
7 6 5 4 3 2 1
5
3
2
4
1
6 7 8 9 10
11 12 13 14 15 16 17
19
18
20
7
6
5
4
3
2
1
8
6
7
8
11
10
9
12
15
13