beautypg.com

KEPCO MAT Full Rack MAT 6V, 15V, 25V AND 36V MODELS User Manual

Page 39

background image

3-10

MAT FULL RACK/ 022300

8. To open the Output Enable relay (disconnect the load from the Power Module), the Host

Computer sends:

OPN :CH9(cr)(lf)

The Power Module relay at address 9 is open

9. To verify the previous command was implemented, the Host Computer sends:

STA(cr)(lf)

The Power Module Controller sends back (if no errors occur)

(sp)(cr)(lf)

3.6.3.1.2 EXAMPLE 2 : PROGRAM NEGATIVE VOLTAGE WITH CURRENT LIMIT

1. To program the Power Module MAT 150-7 to -120 volts with a current limit of 2 amps, the

Host Computer sends:

FNC DCS :CH9 SET VOLT -120 SET CURL 2(cr)(lf)

The MAT at address 9, is then programmed to -120 volts, with a current limit of 2 amps

2. To verify the previous command was implemented the Host Computer sends:

STA(cr)(lf)

The Power Module Controller sends back (if no errors occur):

(sp)(cr)(lf)

3. To enable output (connect the load to the Power Module), the Host Computer sends:

CLS :CH9 (sp)(lf)

The Power Module relay at address 9, closes

4. To verify the previous command was implemented the Host Computer sends:

STA(cr)(lf)

The Power Module Controller sends back (if no errors occur):

(sp)(cr)(lf)

5. To measure the voltage at the output, the Host Computer sends:

FNC DCS VOLT :CH9(cr)(lf)

The MAT at address 9 is now set to take a reading

This manual is related to the following products: