SECTION 3 - OPERATION

3.1

GENERAL

Interconnections linking a stabilized Power Module to an AC power source and a load are criti-
cal. For optimum performance certain rules must be observed. These rules are described in
detail in PAR. 2.6.

3.2

INTRODUCTION TO CONTROLLING THE MAT POWER MODULE OUTPUT

The MAT family of Power Modules communicates remotely with a controller via the Control Bus.
Eac h MAT Power Module has a spec ific address on the bus. The address (from 1 to 31) is
selected by the switches on the top of the unit (see Figures 3-1 and 3-2 and Table 3-1). This
address is set at Kepco to 3.

The MAT family of Power Modules is controlled by the Power Module Controller (see PAR. 1.2).
For an explanation of remote programming refer to PAR 3.6 and Appendices A, B, and C, as
well as the applicable Power Module Controller Manuals.

FIGURE 3-1. TOP COVER ACCESS POINTS