beautypg.com

Retrotec Blower Door with DM32 User Manual

Blower door quickguide

background image

Water in the tube will result in erroneous readings.

Blower Door QuickGuide

Step 1:

Prepare the building

Close outside doors and windows.

Open all interior doors leading to conditioned spaces.

Turn gas, hot water, to Pilot.

Fireplaces and stoves must be cold with doors

closed (cover ashes).

Shut off HVAC, combustion appliances, exhaust fans,

dryers, A/C and furnaces.

See: “Residential Pressure & Air Leakage Testing Manual” for

additional information.

Set up the Door Panel.

See Your Door Panel QuickGuide

Connect the yellow tube between yellow ports

marked “Ref B” on fan and gauge. If the fan has a

green port (“Input B”), connect the green tube.

Connect one end of the Speed Control Cable to the

fan and another to the gauge.

Connect the red tube to the red port on the gauge.

Pass the red tube through the Door Panel and toss

the end at least 5 feet away from the fan’s airstream.

Remove or cover

ashes.

Turn gas valve

to Pilot.

Close all windows

and outside doors.

Place gauge near fan, or attach gauge to Door Panel.

Install the fan blowing outdoors. Cover the fan.

Connect the fan power plug to a wall outlet.

Step 2:

Install the system

QG301 Page 1 of 4 rev-2014-05-16

www.retrotec.com Support: (888)330-1345 International: +1(604)732-0142 Made in Everson, WA USA