RISCO Group eyeWAVE™ User Manual

Eyewave™ wireless pir camera, Installation instructions, 90° 10 m

background image

1

10m

70°

D

D

90°

10

m

eyeWAVE™

Wireless PIR Camera

Installation Instructions

Description

Wireless eyeWave™ is a battery powered PIR detector with an integrated camera, designed for video verification and simple installation by alarm installers. The camera captures and
transmits a sequence of images to a remote server or to mobile phones via RISCO systems, upon an intrusion event or homeowner demand

Main Features

Coverage Patterns

Camera FOV

PIR coverage 12m (40’) wide angle

VGA/VGA camera resolution with ~90° field-of-

view

Discreet IR flash allows imaging in complete

darkness, up to 10m (33’)

Two RF channels with separate antennas:

One for alarms and control; Second channel for

image transmission

Sequence of images upon event, configurable

number and interval and number of images

During unset, events are ignored to save

battery and for privacy

On-demand images initiated from authorized

mobile phone or web browser

Option for on-set image taking

Images stored on detector until transmission to

panel is completed

Includes 2 long-life 3V lithium batteries

Works only with video-supporting systems

PIR Model

Pet Friendly Model

Side view

Top view

Installation

Step1: Preliminary Considerations

Select the mounting location for best coverage of the area that is to be protected (see Coverage Patterns).
Pay attention to the following:

Do not touch the lens with your finger as it will result in blurred image capture.

Do not mount the detector in direct sunlight or near heated sources and metal objects.

Detection sectors should be pointed towards either the wall or the floor and not towards windows and curtains.

Select mounting height according to the coverage patterns (recommended: 2.0–2.4 m in height and at least 40cm from ceiling).

Step 2: Registering the Detector into the system

The eyeWAVE must identify itself to the system receiver in a device allocation (enrollment) process, which can be performed by either RF sequence registering or entering the detector’s
11-digit serial number into the system or using RF mode (Panel Quick Key Programming Sequence:

(From the panel) 1) Radio Devices > 1) Allocation > 1) By RF or 2) By Code.

(Through Configuration Software) Click Allocation > Enter Serial Code: [045] + [8 digits]; Indexed: Automatic or manually designated 1-32; Accessory Type: 2-Way Detector (displayed)).
Then click Allocate: RF Allocation is performed.

Refer to the System Installation manual for full instructions.

Step 3: Mounting the detector

1. Open the knockout holes of the mounting bracket, and use them as a template for mounting according to the following table (see Figure 1).

Mounting position

Knockout for

Left Flat Right

Bracket

7,8 1,2,3,4 5,6

Tamper 9

10

11

For Pet-Friendly Model:

In order to optimize pet immunity the following guide lines are recommended:

Mount the detector vertically at right angles to the floor.

Make sure an animal cannot get above height of 1.5m (5') by climbing on furniture, shelving or stairs.

2. Fasten the cover to the base of the detector by inserting and fastening screw (B) into the hole located inside the battery compartment. (see Figure 3)
3. Insert the batteries and close the battery compartment cover. (see Figure 3)
4. Once the bracket is installed, slide and lock the detector onto the mounting bracket in reverse sequence. (see Figure 2)
5. Perform a Walk Test as described in the Walk Test section.
6. Insert and fasten screw (C) into the hole located at the bottom of the detector to lock the detector to the mounting bracket. (see Figure 3).

Step 4: Walk Test

Upon inserting the batteries, the detector goes into a Walk Test mode for 20 minutes and then automatically returns to Normal mode (To save battery power). During Walk Test Mode,

the detector will transmit after each detection. Walk test the entire field view of the detector and observe the LED for confirmation. Verify that the receiver is properly receiving the
signals

Manually initiate a walk test from the control panel:

Engineer Menu: 2) Testing > 2) Zone > 3) Walk Test 1) Start Walk Test

The detector remains in walk test mode until any key on the panel is pressed. Display test results as follows:

Engineer Menu: 2) Testing > 2) Zone > 3) Walk Test 2) Walk Test Results

Camera Configuration

Being bi-directional, the detectors parameters can be modified from the keypad or from the system configuration software according to your needs:

PIR Sensitivity: High/Low (Default: Low)

Supervision Time: 0-255 minutes (Default: 15 min)

LED: On/Off (Default: On)

Operation

Mode.

Walk Test: The detector will transmit after each detection

Normal (Default)

For more information refer to the System Installer Guide.
Configure the camera settings through the RISCO Configuration Software (right-click on the Serial Code field in the Zones node screen and in the displayed pop-up click Additional..) or
through the panel quick key programming sequence as follows (default in bold):
Programming > 1) Radio Devices > 1) Allocation > 2) Modification > 1) Zones > 1)Parameters > [Select (1–32)] >
6) Advanced 5) Camera Parameters:

1)

Images at Alarm: 3 (1 to 7 images)

2) Image

Interval:

0.5 sec (0.5, 1, 2 seconds)

3) Pre-Alarm

Image:

Yes (Yes, No) (Image capture upon each arm)

4) Image

Resolution:

QVGA (QVGA 320X240, VGA 640X480)

5) Image

Quality:

High (High, Low)

6) Colour

Image:

Colour (Colour, B&W)

D = 2,4 m