RISCO Group iWISE®, iWISE® QUADSEQ Grade 3 User Manual
Page 2

Page 3
Jumper Position Function
Used to determine the sensitivity of the center PIR area.
High
High Sensitivity selection
SENSITIVITY
(Default)
Low: Low Sensitivity selection
Used to determine the polarity of the external input.
(Default)
12V: 12v has to be connected in order to disable the LED’s.
GND or N.C. has no influence on the LED’s status. (see self test jumper configuration)
LED INPUT
0V
0V: The GND has to be connected in order to disable the LED’s.
12v or N.C. has no influence on the LED’s status. (see self test jumper configuration)
Used to determine the relay’s activation logic.
INT: The detector’s alarm activation is determined by the detector’s internal logic. Intruder detection on 
one of the PIR’S detection areas (side or center) activates the appropriate LED only. 
If both PIR’S (side and center) are triggered within a time window of 2 minutes, then both side and 
center relays are activated 
CONF
(Default)
EXT: The security panel determines the detector’s alarm activation. Intruder detection on one of the 
detection zones (side or center) activates the appropriate LED and Relay only. 
Used to determine the operation of the detector’s LEDs
(Default)
ON: LEDs are enabled
Note
:
When an activation signal (see LED Activation jumper for settings) is applied to the LED input of the 
terminal block, LEDs will be disabled.
LED
OFF: LEDs are disabled
Used to test the PIR channels functionality
LOC (Local Self Test): If there is no alarm detection within 1 hour from previous detection, the detector 
will self test both PIR channels. 
In case the local self test fails, the FAULT/AM Relay is activated for a period of 2.5 seconds. 
SELF TEST
(Default)
REM (Remote Self Test): Remote Self Test is activated when the LED terminal input is switched from 
DISABLE to ENABLE mode (see LED Activation jumper for settings). 
In case the remote self test passes, the Alarm Relays are activated for a period of 5 seconds. 
In case the test fails, FAULT/AM Relay is activated for a period of 2.5 seconds. 
EOL 
RESISTORS 
JUMPERS 
The jumpers are used when connecting the detector to a DEOL or TEOL Zone. The jumpers allow the selection of 
TAMPER, TAMPER (upper), ALARM CENTER and ALARM SIDE E.O.L resistors (1K, 2.2K, 4.7K, 5.6K or 6.8K), 
according to the control panel. An additional double jumper allows the connection of 12K FAULT/AM E.O.L resistor (see 
EOL Resistors Scheme). 
TAMPER
EOL
JUMPERS
1K
No 
Resistor 
(Default)
2.2K
4.7K 5.6K
6.8K
TAMPER (upper) EOL JUMPERS
1K
Short
(Default)
2.2K
4.7K
5.6K
6.8K
NONE
ALARM
CENTER
JUMPERS
1K
No 
Resistor 
(Default)
2.2K
4.7K
5.6K
6.8K
ALARM
SIDE EOL
JUMPERS
1K
No 
Resistor 
(Default)
2.2K
4.7K
5.6K
6.8K
FAULT/AM
EOL
JUMPERS
12K
No 
Resistor 
(Default)
EOL Resistors Scheme
Note:
Side & Center area can be connected to DEOL or 
TEOL areas on the panel as illustrated below.  
 
 
TAMPER
ALARM
CENTER
ALARM
SIDE
TAMPER
+12-
LED
FAULT/AM
TEOL ZONE
FAULT AM
ALARM
CENTER
+12-
LED
ALARM SIDE
TAMPER FAULT AM
TAMPER
DEOL/TEOL
ZONE
ALARM SIDE
ALARM
CENTER
TAMPER
ALARM
CENTER
+12-
FAULT AM
LED
DEOL ZONE
ALARM
SIDE
TAMPER
ALARM
CENTER
Page 4
Walk Test
Two minutes after applying power (warm-up period), walk test the Detector over the entire protected area to verify proper operation of the 
unit. 
Important: Always close the front cover prior to applying power to the detector.]
7HFKQLFDO6SHFLILFDWLRQ
Electrical
Current consumption
12mA at 12VDC, 39mA at 
12VDC (max. with all LEDs ON) 
Voltage requirements
9 -16VDC
Alarm contacts
24VDC, 0.1A
Tamper contacts
24VDC, 0.1A
FAULT/AM contacts
24VDC, 0.1A
Environmental
RF immunity
According to EN50130-4
Operating temperature
-20°C to 55°C (-4°F to 130°F)
Storage temperature
-20°C to 60°C (-4°F to 140°F)
Physical
Size
127.6 x 64.2 x 46.6 mm 
(5 x 2.5 x 1.84 in.) 
Weight
115 gr. (4 oz)
2UGHULQJ,QIRUPDWLRQ
Part Number
Description
RK800QS0000A
iWISE QUADSEQ Grade 3
RISCO Group Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 
months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products 
not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product. Seller's obligation and liability under 
this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the 
specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose. 
In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other 
basis of liability whatsoever. 
Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential 
damages or delay. 
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by 
burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and 
maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not assurance or a guarantee that such will not occur or that there 
will be no personal injury or property loss as a result. 
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if 
seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, 
sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or 
representative of Seller is authorized to change this warranty in any way or grant any other warranty. 
 
 
 
 
 
United Kingdom
Tel: +44-161-655-5500 
[email protected] 
Italy
Tel: +39-02-66590054 
[email protected] 
Spain
Tel: +34-91-490-2133 
[email protected] 
France
Tel: +33-164-73-28-50 
[email protected] 
Belgium
Tel: +32-2522-7622 
[email protected] 
USA
Tel: +305-592-3820 
[email protected] 
Brazil
Tel: +55-11-3661-8767 
[email protected] 
China
Tel: +86-21-52-39-0066 
[email protected] 
Poland
Tel: +48-22-500-28-40 
[email protected] 
Israel
Tel: +972-3-963-7777 
[email protected] 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PD6662, EN50131-1, EN50131-2-2 Grade 3 Class II
© RISCO Group 12/08 5IN800QS B