beautypg.com

RISCO Group WL Gas Leak User Manual

Page 2

background image

Page 2

DETECTOR MALFUNCTIONING

A malfunctioning unit is indicated by beep-sounding on and off
sequentially, i.e., beeping for 3 seconds with 3 seconds delay
between two beeps. If this occurs, unplug the detector from the
power source for 10 seconds and then plug the unit again. Should
the unit beep intermittently, DO NOT use this detector. Send the
malfunctioning unit for servicing.

TAKING CARE OF YOUR DETECTOR

You have to maintain the detector frequently to ensure it working
properly. Few tips are provided for you to take care of your
detector:
1.

Use a vacuum cleaner to clean the air vents occasionally to
keep them free of dust.

2.

Push the Test button on your detector to test its operating
function once every week.

LED & BUZZER Indication

The LED light and buzzer turn on and/or off to indicate various
situations. There are four different light and buzzer operations:

Led
Color

Status Meaning

Flashing (for 4
minutes)

Warm up (the status between
Power -Up and Normal operation)

Green
(Power)

On

Normal Condition (Power On)

RED
(Alarm)

Flashing +
Sequential Alarm
Sound

Alarm

Orange
(service)

On

Malfunction/ sensor interruption

ACTIONS TO TAKE WHEN ALARM SOUNDING

In case of harmful levels of gas being detected, your detector will
go into a continuous full alarm. Try to take the following necessary
actions immediately or evacuate the building:
(a) Widely open doors and windows
(b) Disconnect electrical appliances
(b) Avoid open fire
(c) Repair the gas leak by a professional gas repairer

ACTIONS TO TAKE AFTER THE PROBLEM IS
CORRECTED

Once the problem about the gas presence in the premises has
been corrected, the alarm of the detector should be off. After
waiting for 10 minutes, push the Test button to test the detector so
that you can make sure that the detector is working properly again.

SPECIFICATIONS

ELECTRICAL

Power supply:

AC120V - For RWT6GS41100A model

AC230V - For RWT6GS40000A,

RWT6GS80000A models

Frequency:

~50/60Hz

Radio Frequency

868.65 MHz / 433.92 MHz

Supervision
Transmission:

15 min. - For RWT6GS80000A model
65 min. - For RWT6GS40000A model

Response Wave:

Less than 20% in the lower explosion limit

Signal Volume:

Approximately 85 dB at a distance of 3
meters

Sensor Type

Hotwire

PHYSICAL

Size (L X W X H):

140 X 80 X 49 mm

ENVIRONMENTAL

Operating Temperature: 0

qC to 40qC (32qF to 122qF)

Storage Temperature:

-20

qC to 60qC (-4qF to 140qF)

Specifications are subject to change without prior notice. Should any
questions arise please contact your supplier.

ORDERING INFORMATION

P/N Description

RWT6GS80000A

Wireless Gas Leak Detector 868.65 MHz

RWT6GS40000A

Wireless Gas Leak Detector 433.92 MHz

RWT6GS41100A

Wireless Gas Leak Detector 433.92 MHz, 110V

RTTE Compliance Statement

Hereby, RISCO Group declares that this equipment is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC For the CE Declaration of Conformity please refer
to our website: www.riscogroup.com.

RISCO Group Limited Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its
products to be free from defects in materials and workmanship under
normal use for 24 months from the date of production. Because Seller
does not install or connect the product and because the product may
be used in conjunction with products not manufactured by the Seller,
Seller can not guarantee the performance of the security system which
uses this product. Sellers' obligation and liability under this warranty is
expressly limited to repairing and replacing, at Sellers option, within a
reasonable time after the date of delivery, any product not meeting the
specifications. Seller makes no other warranty, expressed or implied,
and makes no warranty of merchantability or of fitness for any
particular purpose. In no case shall seller be liable for any
consequential or incidental damages for breach of this or any other
warranty, expressed or implied, or upon any other basis of liability
whatsoever. Sellers obligation under this warranty shall not include any
transportation charges or costs of installation or any liability for direct,
indirect, or not be compromised or circumvented; that the product will
prevent any persona; injury or property loss by intruder, robbery, fire or
otherwise; or that the product will in all cases provide adequate
warning or protection. Buyer understands that a properly installed and
maintained alarm may only reduce the risk of intruder, robbery or fire
without warning, but is not insurance or a guaranty that such will not
occur or that there will be no personal injury or property loss as a result.
Consequently seller shall have no liability for any personal injury,
property damage or loss based on a claim that the product fails to give
warning. However, if seller is held liable, whether directly or indirectly,
for any loss or damage arising from under this limited warranty or
otherwise, regardless of cause or origin, sellers maximum liability shall
not exceed the purchase price of the product, which shall be complete
and exclusive remedy against seller. No employee or representative of
Seller is authorized to change this warranty in any way or grant any
other warranty.
WARNING: This product should be tested at least once a week.

Contacting RISCO Group

RISCO Group is committed to customer service and product
support. You can contact us through our website
(www.riscogroup.com) or at the following telephone and fax
numbers:

United Kingdom

Tel: +44-161-655-5500

[email protected]

USA

Tel: +305-592-3820

[email protected]

Italy

Tel: +39-02-66590054

[email protected]

Brazil

Tel: +55-11-3661-8767

[email protected]

Spain

Tel: +34-91-490-2133

[email protected]

China

Tel: +86-21-52-39-0066

[email protected]

France

Tel: +33-164-73-28-50

[email protected]

Poland

Tel: +48-22-500-28-40

[email protected]

Belgium

Tel: +32-2522-7622

[email protected]

Israel

Tel: +972-3-963-7777

[email protected]

All rights reserved.
No part of this document may be reproduced in any form without prior
written permission from the publisher.

(CE is for RWT6GS80000A only)

© RISCO Group 09/08

5INT6GS B