beautypg.com

RISCO Group WL Carbon Monoxide User Manual

Page 2

background image

Page 2

TEST/HUSH POWER SERVICE ALARM ALARM VENT

SENSOR VENT

Fig. 5

Testing And Resetting Your Detector

A green power light indicates that power is supplied. To test the detector, press
the Test button. The detector will beep intermittently and the three LEDs will flash.
Release the Test button. The beep and the three LEDs will stop and the green
LED remains on or flashes every 60 seconds.

Muting Your Detector

You can partially mute the detector in an event of alarm by pressing the Test
Button. The Red LED will continue to flash and a short beep will be heard every
16 seconds.

Detector Malfunctioning

A malfunctioning unit is indicated by beep-sounding on and off sequentially, i.e.,
beeping for 3 seconds with 3 seconds delay between two beeps. If this occurs,
remove the batteries from the unit for 10 seconds and then install them again.
Should the unit again beep intermittently, DO NOT use this detector. Send the
malfunctioning unit to the manufacturer for servicing.

Taking Care Of Your Detector

You have to maintain the detector to ensure proper operation:
1.

Use a vacuum cleaner to clean the air vents occasionally to keep them free
of dust.

2.

Press the Test button on your detector to test its operation once every week.

Actions to Take When Alarm Sounding

In case of harmful levels of CO gas being detected, your detector will go into a
continuous full alarm. Try to take the following necessary actions immediately:
(a)

If there is anyone experiencing the effects of carbon monoxide poisoning
such as headache, dizziness, nausea or other flu-like symptoms, call your
fire department or emergency service department right away. You should
evacuate all the people in the premises immediately. Do a head count to
check that everybody is present.

(b)

Do not re-enter the premises until the problem has been corrected and the
CO gas has been dispersed out and a safe level is reached.

(c)

If no symptoms exist, immediately ventilate the home by opening windows
and doors. Turn off fuel burning appliances and call a qualified technician or
your utility company to inspect and repair your problem before restarting
appliances.

WARNING: Normally an activation of the detector indicates the presence of CO
gas. However, the CO gas can be extremely fatal, if it is not detected. The source
of the CO gas may come from several possible situations, please refer to the list
of sources of carbon monoxide in page 1.
CAUTION: This detector will only indicate the presence of CO gas at the sensor.
However, you have to be aware that the CO gas may be present in other areas in
the premises.

Actions to Take After The Problem is Corrected

Once the problem of the CO gas presence in the premises has been corrected,
the detector alarm should be off. After waiting for 10 minutes, push the Test
button to test the detector, and by that, being confident that the detector is working
properly again.

Technical Information

The Carbon Monoxide Detector is engineered to be able to provide alarm sounds
based on the UL standards due to various exposure times at different level of
carbon monoxide concentrations.
According to the Underwriters Laboratories Inc. the carbon monoxide
concentrations and exposure time standards for the alarms have been established
and specified below:
A full alarm is activated under the following conditions:

- between 60 and 90 minutes at exposures of 70 ppm

- between 10 and 30 minutes at exposures of 150 ppm

- between 4 and 10 minutes at exposures of 400 ppm

SPECIFICATIONS
Electrical
Battery Type:

2 x CR 123, 3V Lithium Battery

Current Consumption:

20

µA standby, 30mA Alarm

Frequency:

433.92 MHz or 868.65 MHz

Supervision Transmission:

15 min. - For RWT6C080000A model
65 min. - For RWT6C040000A model

Signal Volume:

85 dB at a distance of 3 meters (10 feet)

Battery Life:

3 years typical

Physical
Size (L X W X H):

140 X 80 X 49 mm
(5.5 inch x 3.2 inch x 2 inch)

Environmental

Operating Temperature:

4

°C to 38°C (39°F to 100°F)

Storage Temperature:

-20

°C to 60°C (-4°F to 140°F)

Based on the requirements of UL 2034 Standard
Specifications are subject to change without prior notice. Should any questions
arise please contact your supplier.

ORDERING INFORMATION

P/N Description
RWT6C080000A

Wireless CO Detector 868.65 MHz

RWT6C040000A

Wireless CO Detector 433.92 MHz

WARNING AND LIMITATION

This detector may not alarm at low carbon monoxide levels. The Occupational
Safety and Health Association (OSHA) has established that continuous exposure
levels of 30 ppm should not be exceeded in an 8 hours period. Individuals with a
medical problem may consider more sensitive detection devices.
The CO gas detector is not suitable as a smoke or fire detector. This detector is
not suitable to install in a hazardous location, as defined in the National Electrical
Code.
This detector will not work without power. RISCO Group's Carbon Monoxide
Detector will not work if the batteries are removed for any reason. Additionally,
carbon monoxide must reach the detector for the proper performance of CO gas
detection.
Carbon monoxide detectors may wear out because they contain electronic parts
that fail at any time. Test your detector at least once week (see the section
"TESTING YOUR DETECTOR"). This CO detector has a limited life span and
should be replaced after five years.

RISCO Group Limited Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects
in materials and workmanship under normal use for 24 months from the date of production. Because
Seller does not install or connect the product and because the product may be used in conjunction with
products not manufactured by the Seller, Seller can not guarantee the performance of the security
system which uses this product. Sellers' obligation and liability under this warranty is expressly limited
to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any
product not meeting the specifications. Seller makes no other warranty, expressed or implied, and
makes no warranty of merchantability or of fitness for any particular purpose. In no case shall seller be
liable for any consequential or incidental damages for breach of this or any other warranty, expressed
or implied, or upon any other basis of liability whatsoever. Sellers obligation under this warranty shall
not include any transportation charges or costs of installation or any liability for direct, indirect, or not be
compromised or circumvented; that the product will prevent any persona; injury or property loss by
intruder, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or
protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk
of intruder, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or
that there will be no personal injury or property loss as a result. Consequently seller shall have no
liability for any personal injury, property damage or loss based on a claim that the product fails to give
warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising
from under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability
shall not exceed the purchase price of the product, which shall be complete and exclusive remedy
against seller. No employee or representative of Seller is authorized to change this warranty in any way
or grant any other warranty.

WARNING: This product should be tested at least once a week.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of
used batteries according to local regulations.

Contacting RISCO Group

RISCO Group is committed to customer service and product support. You can
contact us through our website www.riscogroup.com or as follows:

United Kingdom
Tel: +44-(0)-161-655-5500
E-mail: [email protected]

Brazil
Tel: +55-11-3661-8767
E-mail: [email protected]

Italy
Tel: +39-02-66590054
E-mail: [email protected]

China (Shanghai)
Tel: +86-21-52-39-0066
E-mail: [email protected]

Spain
Tel: +34-91-490-2133
E-mail: [email protected]

China (Shenzhen)

Tel: +86-755-82789285
E-mail: [email protected]

France
Tel: +33-164-73-28-50
E-mail: [email protected]

Poland
Tel: +48-22-500-28-40
E-mail: [email protected]

Belgium (Benelux)
Tel: +32-2522-7622
E-mail: [email protected]

Israel
Tel: +972-3-963-7777
E-mail: [email protected]

USA
Tel: +1-631-719-4400
E-mail: [email protected]

RISCO product was purchased from

All rights reserved.
No part of this document may be reproduced in any form without prior written
permission from the publisher.

(CE is for RWT6CO80000A only)

©

RISCO

Group

09/11

5INT6CO

D