beautypg.com

Input – Precision Digital PD663 User Manual

Page 8

background image

PD663 Loop-Powered Meter

Instruction Manual

8

Input

ACCURACY

±1 count

FUNCTION

Linear (2 to 32 points) or square root

TEMPERATURE
DRIFT

50 PPM/

C from -40 to 75C ambient

DECIMAL POINT

User selectable decimal point

MINIMUM SPAN

Input 1 & Input 2: 0.40 mA

CALIBRATION
RANGE

An Error message will appear if input 1 and input 2 signals
are too close together.
Input
Range

Minimum Span
Input 1 & Input 2

4-20 mA 0.40 mA

MAXIMUM
VOLTAGE DROP

Without Backlight

With Backlight

1.7 VDC @ 20 mA

4.7 VDC @ 20 mA

EQUIVALENT
RESISTANCE

85 Ω @ 20 mA

185 Ω @ 20 mA

LOOP-POWERED
BACKLIGHT
OPTION

Factory installed only. Powered directly from the 4-20 mA
loop, no batteries required. Backlight can be enabled or
disabled via alternative wiring of terminal block. The
display brightness will increase as the input signal current
increases.

INPUT
OVERLOAD

Over current protection to 2 A max.