beautypg.com

Specifications, General – Precision Digital PD663 User Manual

Page 7

background image

PD663 Loop-Powered Meter

Instruction Manual

7

SPECIFICATIONS

Except where noted all specifications apply to operation at +25°C.

General

DISPLAY

0.6" (15.24 mm) LCD, 3½+ digits; -1999 to 2999

DISPLAY
UPDATE RATE

2 Updates/Second

OVERRANGE

Display flashes

2999

UNDERRANGE

Display flashes

-1999

PROGRAMMING
METHOD

Four internal pushbuttons, optional magnetic reed
switches.

NOISE FILTER

Programmable HI, LO, or OFF

RECALIBRATION

Recalibration is recommended at least every 12 months.

MAX/MIN
DISPLAY

Max/Min readings reached by the process are stored until
reset by the user or until power to the meter is turned off.

NON-VOLATILE
MEMORY

All programmed settings are stored in non-volatile memory
for a minimum of ten years if power is lost.

NORMAL MODE
REJECTION

64 dB at 50/60 Hz

ENVIRONMENTAL

Operating temperature range: -40 to 75°C
Storage temperature range: -40 to 75°C
Relative humidity: 0 to 90% non-condensing

CONNECTIONS

Removable screw terminals accept 12 to 22 AWG wire

ENCLOSURE

Explosion-proof die cast aluminum with glass window,
0.30% max copper content, corrosion resistant epoxy
coating, color: blue. NEMA 4X, 7, & 9, IP68.
Two ½” NPT threaded conduit openings. One ½” NPT
nickel plated brass conduit plug with 10 mm hex key fitting
installed.

MOUNTING

May be mounted directly to conduit. Two mounting holes
for 1.5” pipe or wall mounting. See Mounting Dimensions
on page 32.

TIGHTENING
TORQUE

Screw terminal electrical connectors: 4.5 lb-in (0.5 Nm)

OVERALL
DIMENSIONS

4.84" x 4.29" x 3.62" (123 mm x 109 mm x 92 mm)
(W x H x D)

WEIGHT

2.45 lbs (40 oz, 1.13 kg)

WARRANTY

3 years parts and labor