Process input, D.ddd, dd.dd, ddd.d – Precision Digital PD603 User Manual
Page 7

Sabre P Model PD603 Process Meter
Instruction Manual
7
ENCLOSURE
1/8 DIN, high impact plastic, UL 94V-0, color: gray
MOUNTING
1/8 DIN panel cutout required. Two panel mounting brack-
et assemblies provided 
TIGHTENING 
TORQUE 
Screw terminal connectors: 4.5 lb-in (0.5 Nm)
OVERALL 
DIMENSIONS 
2.45" x 4.68" x 4.19" (62 mm x 119 mm x 106 mm) 
(H x W x D) 
WEIGHT
8.5 oz (241 g)
WARRANTY
1 year parts & labor
EXTENDED 
WARRANTY 
1 or 2 years, refer to the Price List for details.
Process Input
INPUTS
Field selectable: 
0-20, 4-20 mA, 0-5, 1-5, 0-10 V, or 
10 V
ACCURACY
±0.05% FS ±1 count
FUNCTION
Linear
TEMPERATURE 
DRIFT 
50 PPM/
C from 0 to 65C ambient
DECIMAL POINT Up to three decimal places:
d.ddd, dd.dd, ddd.d,
or
dddd
CALIBRATION 
RANGE 
An Error message will appear if input 1 and input 2 signals 
are too close together. 
Input 
Range 
Minimum Span 
Input 1 & Input 2 
4-20 mA 0.40 mA 
10 V 
0.20 V
INPUT 
IMPEDANCE 
Voltage ranges: greater than 1 M
Current ranges: 50 - 100
(depending on resettable fuse impedance)
INPUT 
OVERLOAD 
Current input protected by resettable fuse. 
Fuse resets automatically after fault is removed. 