Specifications, General – Precision Digital PD603 User Manual
Page 6
![background image](https://www.manualsdir.com/files/858260/content/doc006.png)
Sabre P Model PD603 Process Meter
Instruction Manual
6
SPECIFICATIONS
Except where noted all specifications apply to operation at +25°C.
General
DISPLAY
0.56" (14 mm) high, red LED
Four digits (-1999 to 9999), automatic lead zero blanking.
DISPLAY
UPDATE RATE
5/second
OVERRANGE
Display flashes
9999
UNDERRANGE
Display flashes
-1999
PROGRAMMING
METHODS
Four front panel buttons
RECALIBRATION
All ranges are calibrated at the factory.
Recalibration is recommended at least every 12 months.
MAX/MIN
DISPLAY
Max/min readings reached by the process are stored until
reset by the user or until power to the meter is turned off.
PASSWORD
Programmable password restricts modification of
programmed settings.
NON-VOLATILE
MEMORY
All programmed settings are stored in non-volatile memory
for a minimum of ten years if power is lost.
POWER
OPTIONS
85-265 VAC, 50/60 Hz; 90-265 VDC, 20 W max
or 12-36 VDC, 12-24 VAC, 6 W max
FUSE
Required fuse: UL Recognized, 5 A max, slow blow
Up to 6 meters may share one 5 A fuse
ISOLATED
TRANSMITTER
POWER SUPPLY
P+, P- terminals: 24 VDC
10% @ 200 mA max
NORMAL MODE
REJECTION
64 dB at 50/60 Hz
ISOLATION
4 kV input-to-power line
500 V input-to-24 V supply
OVERVOLTAGE
CATEGORY
Installation Overvoltage Category II:
Local level with smaller transient overvoltages than Instal-
lation Overvoltage Category III.
ENVIRONMENTAL Operating temperature range: 0 to 65°C
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing
CONNECTIONS
Removable screw terminal blocks accept 12 to 22 AWG
wire, RJ11 for factory use only.