beautypg.com

Connections, Connector labeling, Power connections – Precision Digital PD603 User Manual

Page 11: Figure 3. power connections

background image

Sabre P Model PD603 Process Meter

Instruction Manual

11

Connections

All connections are made to removable screw terminal connectors
located at the rear of the meter.

!

Use copper wire with 60°C or 60/75°C insulation
for all line voltage connections. Observe all safety
regulations. Electrical wiring should be performed
in accordance with all applicable national, state,
and local codes to prevent damage to the meter
and ensure personnel safety.

Connector Labeling

The connectors label, affixed to the meter, shows the location of the
connectors available with requested configuration.

24V OUT

DW1911

POWER

X

X

V+

mA+

COM

Factory

Use

Only

3

4

1

2

5

2

1

2

1

P+

P-

+

-

SIGNAL

Figure 2. Connector Labeling - Meter with 24 V Supply

Power Connections

Power connections are made to a two-terminal connector labeled POW-
ER on Figure 2. The meter will operate regardless of DC polarity connec-
tion. The + and - symbols are only a suggested wiring convention.

1

2

AC or DC

POWER

Required External Fuse:

5 A max, Slow Blow

POWER CONNECTOR

+

-

Figure 3. Power Connections